Complete Set of CAMPUS® Data, ASTM Data, Biopolymer Database, Application Database, Tradename Database, Literature Database, Toolbox.

Material datasheets available free. Online registration at: www.materialdatacenter.com

Material Data Center is a leading international information system for the plastics industry. Material Data Center offers a comprehensive plastics database, calculation tools, CAE interfaces, a literature database and an application database. For more information about Material Data Center visit www.materialdatacenter.com.

This is the free Material Data Center Datasheet of IMPET® 330R - PET-GF30 - Celanese

Material Data Center offers the following functions for IMPET® 330R:
unit conversion, PDF datasheet print, comparison with other plastics, snap fit calculation, beam deflection calculation, CAE Interfaces

Check here, which other Impet datasheets, application examples or technical articles are available in Material Data Center

Use the following short links to get directly to the properties of interest in this datasheet:
Any use of this information falls under the rules of our disclaimer.
Processing/Physical CharacteristicsValueUnitTest Standard
ISO Data
Molding shrinkage, parallel 0.2 % ISO 294-4, 2577
Molding shrinkage, normal 0.6 % ISO 294-4, 2577
Mechanical propertiesValueUnitTest Standard
ISO Data
Tensile Modulus 11000 MPa ISO 527
Stress at break 160 MPa ISO 527
Strain at break 2.3 % ISO 527
Charpy impact strength, +23°C 27 kJ/m² ISO 179/1eU
Charpy impact strength, -30°C 28 kJ/m² ISO 179/1eU
Charpy notched impact strength, +23°C 8.5 kJ/m² ISO 179/1eA
Charpy notched impact strength, -30°C 8.8 kJ/m² ISO 179/1eA
Shore D hardness 86 - ISO 7619-1
Thermal propertiesValueUnitTest Standard
ISO Data
Melting temperature, 10°C/min 244 °C ISO 11357-1/-3
Glass transition temperature, 10°C/min 73 °C ISO 11357-1/-2
Temp. of deflection under load, 1.80 MPa 221 °C ISO 75-1/-2
Temp. of deflection under load, 0.45 MPa 240 °C ISO 75-1/-2
Coeff. of linear therm. expansion, parallel 18 E-6/K ISO 11359-1/-2
Coeff. of linear therm. expansion, normal 70 E-6/K ISO 11359-1/-2
Oxygen index 25 % ISO 4589-1/-2
Electrical propertiesValueUnitTest Standard
ISO Data
Relative permittivity, 100Hz 2.83 - IEC 62631-2-1
Relative permittivity, 1MHz 3.46 - IEC 62631-2-1
Dissipation factor, 100Hz 120 E-4 IEC 62631-2-1
Dissipation factor, 1MHz 140 E-4 IEC 62631-2-1
Volume resistivity >1E13 Ohm*m IEC 62631-3-1
Surface resistivity >1E15 Ohm IEC 62631-3-2
Electric strength 32 kV/mm IEC 60243-1
Other propertiesValueUnitTest Standard
Humidity absorption 0.16 % Sim. to ISO 62
Density 1580 kg/m³ ISO 1183
Processing Recommendation Injection MoldingValueUnitTest Standard
Pre-drying - Temperature 121 °C -
Pre-drying - Time 4 h -
Processing humidity ≤0.01 % -
Melt temperature 270 - 300 °C -
Mold temperature 110 - 120 °C -
Characteristics
Processing
Injection Molding
Delivery form
Pellets
Additives
Lubricants
Regional Availability
North America, Europe, Asia Pacific, South and Central America, Near East/Africa
Other text information
Injection molding
To avoid hydrolytic degradation during processing, IMPET resins have to be dried to a moisture level equal to or less than 0.01%. Drying should be done in a dehumidifying hopper dryer capable of dewpoints <-30°F (-34°C) at 275°F (121°C) for 4 hours.
Rear Temperature 500-520(260-270) deg F (deg C)
Center Temperature 520-530(270-275) deg F (deg C)
Front Temperature 530-540(275-280) deg F (deg C)
Nozzle Temperature 530-550(275-290) deg F (deg C)
Melt Temperature 520-570(270-300) deg F (deg C)
Mold Temperature 230-250(110-120) deg F (deg C)
Back Pressure 0-25 psi
Screw Speed 50-75 rpm
Injection Speed Medium/Fast

Injection speed, injection pressure and holding pressure have to be optimized to the individual article geometry. To avoid material degradation during processing low back pressure and minimum screw speed have to be used. Overheating of the material has to be avoided, in particular for flame retardant grades. Up to 25% clean and dry regrind may be used.
Disclaimer
Copyright Altair Engineering GmbH. Altair Engineering GmbH assumes no liability for the system to be free of errors. The user takes sole responsibility for the use of this data under the exclusion of every liability from Altair Engineering GmbH; this is especially valid for claims of compensation resulting from consequential damages. Altair explicitly points out that any decision about the application of materials must be double checked with the producer of this material. This includes all contents of this system. Copyright laws are applicable for the content of this system.
Created: Source: www.materialdatacenter.com


Material Data Center is provided by M-Base Engineering + Software GmbH. M-Base Engineering + Software GmbH assumes no liability for the system to be free of errors. Any decision about the application of materials must be double checked with the producer of this material.

Additional information about this material, like producer contact address, etc. can be found at www.materialdatacenter.com. For access to this extra information a registration is requested. Free online registration is available.