Complete Set of CAMPUS® Data, ASTM Data, Biopolymer Database, Application Database, Tradename Database, Literature Database, Toolbox.

Material datasheets available free. Online registration at: www.materialdatacenter.com

Material Data Center is a leading international information system for the plastics industry. Material Data Center offers a comprehensive plastics database, calculation tools, CAE interfaces, a literature database and an application database. For more information about Material Data Center visit www.materialdatacenter.com.

This is the free Material Data Center Datasheet of LATAMID 66 B H-V0 - (PA66+PA6) - LATI Industria Termoplastici S.p.A.

Material Data Center offers the following functions for LATAMID 66 B H-V0:
unit conversion, PDF datasheet print, comparison with other plastics, snap fit calculation, beam deflection calculation, CAE Interfaces

Check here, which other Latamid datasheets, application examples or technical articles are available in Material Data Center

Use the following short links to get directly to the properties of interest in this datasheet:
Any use of this information falls under the rules of our disclaimer.
Processing/Physical CharacteristicsValueUnitTest Standard
ISO Data
Molding shrinkage, parallel 1.4 % ISO 294-4, 2577
Molding shrinkage, normal 1.2 % ISO 294-4, 2577
Mechanical propertiesValueUnitTest Standard
ISO Data
Tensile Modulus 3800 MPa ISO 527
Yield stress 80 MPa ISO 527
Yield strain 4 % ISO 527
Stress at break 80 MPa ISO 527
Strain at break 8 % ISO 527
Charpy impact strength, +23°C 55 kJ/m² ISO 179/1eU
Charpy notched impact strength, +23°C 3 kJ/m² ISO 179/1eA
Thermal propertiesValueUnitTest Standard
ISO Data
Temp. of deflection under load, 1.80 MPa 90 °C ISO 75-1/-2
Temp. of deflection under load, 0.45 MPa 235 °C ISO 75-1/-2
Vicat softening temperature, B 240 °C ISO 306
Coeff. of linear therm. expansion, parallel 110 E-6/K ISO 11359-1/-2
Glow Wire Flammability Index (GWFI) 960 °C IEC 60695-2-12
GWFI - thickness tested (1) 1 mm -
Glow Wire Flammability Index (GWFI) 960 °C IEC 60695-2-12
GWFI - thickness tested (2) 2 mm -
ASTM Data
UL 94 Flame rating V-0 - UL 94
Thickness tested 0.75 mm -
Limiting Oxygen Index 32 % ASTM D 2863
Electrical propertiesValueUnitTest Standard
ISO Data
Comparative tracking index 525 - IEC 60112
ASTM Data
Surface Resistivity 1E12 Ohm ASTM D 257
Other propertiesValueUnitTest Standard
Density 1160 kg/m³ ISO 1183
Processing Recommendation Injection MoldingValueUnitTest Standard
Pre-drying - Temperature 90 - 100 °C -
Pre-drying - Time 3 h -
Melt temperature 265 - 275 °C -
Mold temperature 70 - 100 °C -
Characteristics
Processing
Injection Molding
Special Characteristics
Flame retardant, Halogen-free, Phosphorus-free, Heat stabilized or stable to heat
Regional Availability
Europe
Disclaimer
Copyright Altair Engineering GmbH. Altair Engineering GmbH assumes no liability for the system to be free of errors. The user takes sole responsibility for the use of this data under the exclusion of every liability from Altair Engineering GmbH; this is especially valid for claims of compensation resulting from consequential damages. Altair explicitly points out that any decision about the application of materials must be double checked with the producer of this material. This includes all contents of this system. Copyright laws are applicable for the content of this system.
Created: Source: www.materialdatacenter.com


Material Data Center is provided by M-Base Engineering + Software GmbH. M-Base Engineering + Software GmbH assumes no liability for the system to be free of errors. Any decision about the application of materials must be double checked with the producer of this material.

Additional information about this material, like producer contact address, etc. can be found at www.materialdatacenter.com. For access to this extra information a registration is requested. Free online registration is available.