Complete Set of CAMPUS® Data, ASTM Data, Biopolymer Database, Application Database, Tradename Database, Literature Database, Toolbox.

Material datasheets available free. Online registration at: www.materialdatacenter.com

Material Data Center is a leading international information system for the plastics industry. Material Data Center offers a comprehensive plastics database, calculation tools, CAE interfaces, a literature database and an application database. For more information about Material Data Center visit www.materialdatacenter.com.

This is the free Material Data Center Datasheet of MABLEX® 274 - (PC+ABS) - Ravago Group

Material Data Center offers the following functions for MABLEX® 274:
unit conversion, PDF datasheet print, comparison with other plastics

Check here, which other Mablex datasheets, application examples or technical articles are available in Material Data Center

Use the following short links to get directly to the properties of interest in this datasheet:
Any use of this information falls under the rules of our disclaimer.
Processing/Physical CharacteristicsValueUnitTest Standard
ISO Data
Melt flow index, MFI 13 g/10min ISO 1133
Temperature 260 °C -
Load 5 kg -
Molding shrinkage, parallel 0.6 % ISO 294-4, 2577
Mechanical propertiesValueUnitTest Standard
ISO Data
Yield stress 58 MPa ISO 527
Stress at break 48 MPa ISO 527
Strain at break 52 % ISO 527
Flexural modulus, 23°C 2400 MPa ISO 178
Izod notched impact strength, +23°C 55 kJ/m² ISO 180/1A
Izod notched impact strength 30 kJ/m² ISO 180/1A
Temperature -30 °C -
Thermal propertiesValueUnitTest Standard
ISO Data
Temp. of deflection under load, 1.80 MPa 110 °C ISO 75-1/-2
Vicat softening temperature, A 132 °C ISO 306
Vicat softening temperature, B 124 °C ISO 306
Burning behav. at 1.5 mm nom. thickn. HB class IEC 60695-11-10
Thickness tested 1.6 mm -
Burning behav. at thickness h HB class IEC 60695-11-10
Thickness tested 3.2 mm -
Burning rate, FMVSS, Thickness 1 mm 48 mm/min ISO 3795 (FMVSS 302)
Glow Wire Flammability Index (GWFI) 650 °C IEC 60695-2-12
GWFI - thickness tested (1) 2 mm -
Electrical propertiesValueUnitTest Standard
ISO Data
Volume resistivity 1E13 Ohm*m IEC 62631-3-1
Surface resistivity 1E14 Ohm IEC 62631-3-2
Electric strength 24 kV/mm IEC 60243-1
Comparative tracking index 300 - IEC 60112
Other propertiesValueUnitTest Standard
Density 1130 kg/m³ ISO 1183
Processing Recommendation Injection MoldingValueUnitTest Standard
Pre-drying - Temperature 100 °C -
Pre-drying - Time 3 - 4 h -
Processing humidity ≤0.05 % -
Melt temperature 250 - 270 °C -
Mold temperature 50 - 80 °C -
Zone 1 225 - 240 °C -
Zone 2 240 - 260 °C -
Zone 3 260 - 270 °C -
Nozzle temperature 250 - 260 °C -
Screw speed 40 - 70 rpm -
Back pressure 0.3 - 1.5 MPa -
Holding pressure 3 - 7 MPa -
Characteristics
Processing
Injection Molding
Special Characteristics
Heat stabilized or stable to heat
Regional Availability
Europe
Disclaimer
Copyright Altair Engineering GmbH. Altair Engineering GmbH assumes no liability for the system to be free of errors. The user takes sole responsibility for the use of this data under the exclusion of every liability from Altair Engineering GmbH; this is especially valid for claims of compensation resulting from consequential damages. Altair explicitly points out that any decision about the application of materials must be double checked with the producer of this material. This includes all contents of this system. Copyright laws are applicable for the content of this system.
Created: Source: www.materialdatacenter.com


Material Data Center is provided by M-Base Engineering + Software GmbH. M-Base Engineering + Software GmbH assumes no liability for the system to be free of errors. Any decision about the application of materials must be double checked with the producer of this material.

Additional information about this material, like producer contact address, etc. can be found at www.materialdatacenter.com. For access to this extra information a registration is requested. Free online registration is available.