Complete Set of CAMPUS® Data, ASTM Data, Biopolymer Database, Application Database, Tradename Database, Literature Database, Toolbox.

Material datasheets available free. Online registration at: www.materialdatacenter.com

Material Data Center is a leading international information system for the plastics industry. Material Data Center offers a comprehensive plastics database, calculation tools, CAE interfaces, a literature database and an application database. For more information about Material Data Center visit www.materialdatacenter.com.

This is the free Material Data Center Datasheet of VESTAKEEP® i2 UFP10 - PEEK - Evonik Operations GmbH

Material Data Center offers the following functions for VESTAKEEP® i2 UFP10:
unit conversion, PDF datasheet print, comparison with other plastics, snap fit calculation, beam deflection calculation, CAE Interfaces

Check here, which other Vestakeep datasheets, application examples or technical articles are available in Material Data Center

Use the following short links to get directly to the properties of interest in this datasheet:
Any use of this information falls under the rules of our disclaimer.
Product Texts
Ultra-fine polyether ether ketone (PEEK) powder for permanent implants
 
VESTAKEEP® i2 UFP10 is an unreinforced, medium-viscosity, natural colored polyether ether ketone (PEEK) ultra-fine powder.

VESTAKEEP® i2 UFP10 is especially designed for long term implantable medical devices.

The semi-crystalline polymer is designed for high biocompatibility and superior mechanical, thermal and chemical resistance.

Proven Biocompatibility of VESTAKEEP® i-Grades
The biocompatibility of VESTAKEEP® i2 UFP10 has been tested following ISO 10993 recommendations for permanent tissue/bone contact. The material complies USP Class VI.

VESTAKEEP® i2 UFP10 is compliant with ASTM F2026 “Standard Specification for Polyetheretherketone (PEEK) Polymers for Surgical Implant Applications”.

A summary of biocompatibility tests is available upon request.

Biocompatibility test reports available for i2 UFP10

 
In addition to the body contact period the suitability of the material depends on further criteria, for example the nature of the contact, the processing, or the surface. In any case the suitability has to be verified for the end product.

Processing of VESTAKEEP® i-Grades
For information about processing of VESTAKEEP® i2 UFP10, please follow the general recommendations in our brochure “High Performance in Powder Form - Polyether Ether Ketone Powders“.

Delivery of VESTAKEEP® i-Grades
VESTAKEEP® i2 UFP10 is supplied as a powder in 15 kg boxes or 5 kg buckets with moisture-proof polyethylene liners.


FOR FURTHER INFORMATION PLEASE CONTACT US AT EVONIK-HP@EVONIK.COM
OR VISIT OUR PRODUCT AT  WWW.EVONIK.COM/MEDICAL-TECHNOLOGY
Processing/Physical CharacteristicsValueUnitTest Standard
ISO Data
Melt volume-flow rate, MVR 70 cm³/10min ISO 1133
Temperature 380 °C -
Load 5 kg -
Mechanical propertiesValueUnitTest Standard
ISO Data
Tensile Modulus 3700 MPa ISO 527
Yield stress 100 MPa ISO 527
Yield strain 5 % ISO 527
Nominal strain at break 30 % ISO 527
Charpy impact strength, +23°C N kJ/m² ISO 179/1eU
Charpy impact strength, -30°C N kJ/m² ISO 179/1eU
Charpy notched impact strength, +23°C 6 kJ/m² ISO 179/1eA
Type of failure C - -
Charpy notched impact strength, -30°C 6 kJ/m² ISO 179/1eA
Type of failure C - -
Thermal propertiesValueUnitTest Standard
ISO Data
Melting temperature, 10°C/min 340 °C ISO 11357-1/-3
Temp. of deflection under load, 1.80 MPa 155 °C ISO 75-1/-2
Temp. of deflection under load, 0.45 MPa 205 °C ISO 75-1/-2
Vicat softening temperature, B 310 °C ISO 306
Other propertiesValueUnitTest Standard
Density 1300 kg/m³ ISO 1183
Characteristics
Processing
Coating, Transfer Molding
Delivery form
Powder, Natural Color
Features
Thermal Stability
Chemical Resistance
General Chemical Resistance
Certifications
Medical Grade, Biocompatibility ISO 10993, US Pharmacopeia Class VI Approved
Applications
Medical
Regional Availability
Disclaimer
Copyright Altair Engineering GmbH. Altair Engineering GmbH assumes no liability for the system to be free of errors. The user takes sole responsibility for the use of this data under the exclusion of every liability from Altair Engineering GmbH; this is especially valid for claims of compensation resulting from consequential damages. Altair explicitly points out that any decision about the application of materials must be double checked with the producer of this material. This includes all contents of this system. Copyright laws are applicable for the content of this system.
Created: Source: www.materialdatacenter.com


Material Data Center is provided by M-Base Engineering + Software GmbH. M-Base Engineering + Software GmbH assumes no liability for the system to be free of errors. Any decision about the application of materials must be double checked with the producer of this material.

Additional information about this material, like producer contact address, etc. can be found at www.materialdatacenter.com. For access to this extra information a registration is requested. Free online registration is available.