Complete Set of CAMPUS® Data, ASTM Data, Biopolymer Database, Application Database, Tradename Database, Literature Database, Toolbox.

Material datasheets available free. Online registration at: www.materialdatacenter.com

Material Data Center is a leading international information system for the plastics industry. Material Data Center offers a comprehensive plastics database, calculation tools, CAE interfaces, a literature database and an application database. For more information about Material Data Center visit www.materialdatacenter.com.

This is the free Material Data Center Datasheet of VESTAMID® L-GF15 - PA12-GF15 - Evonik Operations GmbH

Material Data Center offers the following functions for VESTAMID® L-GF15:
unit conversion, PDF datasheet print, comparison with other plastics, snap fit calculation, beam deflection calculation, parameters for material models, CAE Interfaces

Check here, which other Vestamid datasheets, application examples or technical articles are available in Material Data Center

Use the following short links to get directly to the properties of interest in this datasheet:
Any use of this information falls under the rules of our disclaimer.
Product Texts

Glass fibre reinforced (15%) PA12 resin for the injection moulding of rigid and tough parts

VESTAMID® L-GF15 NC is a glass fiber –reinforced heat stabilized Polyamide 12 for injection molding. The material contains about 15% glass fibers, an ageing protective agent and a processing aid for a fast and even form filling. Due to the reinforcement moldings from this compound exhibit a higher strength and good heat resistance, excellent for gear housings for electric window openers in cars.

Further advantages of VESTAMID® L-GF15 NC are the characterizing properties of PA12, e.g., low water absorption, good dimensional stability and nearly constant mechanical properties at changing ambient humidity.
  
VESTAMID® L-GF15 NC is supplied as cylindrical granules, ready for processing, in moisture-proof bags.
 
Pigmentation may affect values.

Inside the original and undamaged packaging, the product has a shelf life of at least 2 years when stored in dry rooms at temperatures not exceeding 30°C.

For information about processing of VESTAMID®, please follow the general commendations about “Processing of VESTAMID® compounds”. 

FOR FURTHER INFORMATION PLEASE CONTACT US AT EVONIK-HP@EVONIK.COM

OR VISIT OUR PRODUCT AT  WWW.VESTAMID.COM
Processing/Physical Characteristicsdry / condUnitTest Standard
ISO Data
Melt volume-flow rate, MVR 55 / * cm³/10min ISO 1133
Temperature 275 / * °C -
Load 5 / * kg -
Molding shrinkage, parallel 0.3 / * % ISO 294-4, 2577
Molding shrinkage, normal 0.7 / * % ISO 294-4, 2577
Mechanical propertiesdry / condUnitTest Standard
ISO Data
Tensile Modulus 4200 / 3600 MPa ISO 527
Yield stress 90 / 81 MPa ISO 527
Yield strain 4 / 4 % ISO 527
Nominal strain at break 5 / 4 % ISO 527
Charpy impact strength, +23°C 64 / 49 kJ/m² ISO 179/1eU
Type of failure C / C - -
Charpy impact strength, -30°C 80 / 55 kJ/m² ISO 179/1eU
Type of failure C / C - -
Charpy notched impact strength, +23°C 12 / 9 kJ/m² ISO 179/1eA
Type of failure C / C - -
Charpy notched impact strength, -30°C 11 / 7 kJ/m² ISO 179/1eA
Type of failure C / C - -
Thermal propertiesdry / condUnitTest Standard
ISO Data
Melting temperature, 10°C/min 178 / * °C ISO 11357-1/-3
Temp. of deflection under load, 1.80 MPa 160 / * °C ISO 75-1/-2
Temp. of deflection under load, 0.45 MPa 175 / * °C ISO 75-1/-2
Vicat softening temperature, B 170 / * °C ISO 306
Coeff. of linear therm. expansion, parallel 80 / * E-6/K ISO 11359-1/-2
Burning Behav. at 1.5 mm nom. thickn. HB / * class IEC 60695-11-10
Thickness tested 1.6 / * mm -
Yellow Card available yes / * - -
Yellow Card available yes / * - -
Electrical propertiesdry / condUnitTest Standard
ISO Data
Relative permittivity, 100Hz 4 / 5.2 - IEC 62631-2-1
Relative permittivity, 1MHz 3.4 / 3.3 - IEC 62631-2-1
Dissipation factor, 100Hz 380 / - E-4 IEC 62631-2-1
Dissipation factor, 1MHz 260 / 450 E-4 IEC 62631-2-1
Volume resistivity >1E13 / 1.8E12 Ohm*m IEC 62631-3-1
Electric strength 50 / 47 kV/mm IEC 60243-1
Comparative tracking index 600 / - - IEC 60112
Other propertiesdry / condUnitTest Standard
Water absorption 1.3 / * % Sim. to ISO 62
Humidity absorption 0.6 / * % Sim. to ISO 62
Density 1120 / - kg/m³ ISO 1183
Diagrams
Viscosity-shear rate , VESTAMID® L-GF15, PA12-GF15, Evonik
Shearstress-shear rate , VESTAMID® L-GF15, PA12-GF15, Evonik
Dynamic Shear modulus-temperature , VESTAMID® L-GF15 (dry), PA12-GF15, Evonik
Stress-strain , VESTAMID® L-GF15 (dry), PA12-GF15, Evonik
Secant modulus-strain , VESTAMID® L-GF15 (dry), PA12-GF15, Evonik
Stress-strain (isochronous) 23°C, VESTAMID® L-GF15 (cond.), PA12-GF15, Evonik
Creep modulus-time 23°C, VESTAMID® L-GF15 (cond.), PA12-GF15, Evonik
Creep curve 23°C, VESTAMID® L-GF15 (cond.), PA12-GF15, Evonik
Tensile modulus-temperature , VESTAMID® L-GF15 (dry), PA12-GF15, Evonik
Characteristics
Processing
Injection Molding
Delivery form
Pellets, Natural Color
Additives
Lubricants
Special Characteristics
Heat stabilized or stable to heat
Applications
Automotive
Regional Availability
Disclaimer
Copyright Altair Engineering GmbH. Altair Engineering GmbH assumes no liability for the system to be free of errors. The user takes sole responsibility for the use of this data under the exclusion of every liability from Altair Engineering GmbH; this is especially valid for claims of compensation resulting from consequential damages. Altair explicitly points out that any decision about the application of materials must be double checked with the producer of this material. This includes all contents of this system. Copyright laws are applicable for the content of this system.
Created: Source: www.materialdatacenter.com


Material Data Center is provided by M-Base Engineering + Software GmbH. M-Base Engineering + Software GmbH assumes no liability for the system to be free of errors. Any decision about the application of materials must be double checked with the producer of this material.

Additional information about this material, like producer contact address, etc. can be found at www.materialdatacenter.com. For access to this extra information a registration is requested. Free online registration is available.