Complete Set of CAMPUS® Data, ASTM Data, Biopolymer Database, Application Database, Tradename Database, Literature Database, Toolbox.

Material datasheets available free. Online registration at: www.materialdatacenter.com

Material Data Center is a leading international information system for the plastics industry. Material Data Center offers a comprehensive plastics database, calculation tools, CAE interfaces, a literature database and an application database. For more information about Material Data Center visit www.materialdatacenter.com.

This is the free Material Data Center Datasheet of VESTAMID® D16 - PA612 - Evonik Operations GmbH

Material Data Center offers the following functions for VESTAMID® D16:
unit conversion, PDF datasheet print, comparison with other plastics, snap fit calculation, beam deflection calculation, parameters for material models, CAE Interfaces

Check here, which other Vestamid datasheets, application examples or technical articles are available in Material Data Center

Use the following short links to get directly to the properties of interest in this datasheet:
Any use of this information falls under the rules of our disclaimer.
Processing/Physical Characteristicsdry / condUnitTest Standard
ISO Data
Melt volume-flow rate, MVR 75 / * cm³/10min ISO 1133
Temperature 240 / * °C -
Load 5 / * kg -
Molding shrinkage, parallel 1.3 / * % ISO 294-4, 2577
Molding shrinkage, normal 1.4 / * % ISO 294-4, 2577
Mechanical propertiesdry / condUnitTest Standard
ISO Data
Tensile Modulus 2200 / 1700 MPa ISO 527
Yield stress 58 / 53 MPa ISO 527
Yield strain 4 / 16 % ISO 527
Nominal strain at break >50 / >50 % ISO 527
Charpy impact strength, +23°C N / N kJ/m² ISO 179/1eU
Charpy impact strength, -30°C N / N kJ/m² ISO 179/1eU
Charpy notched impact strength, +23°C 5 / 6 kJ/m² ISO 179/1eA
Type of failure C / C - -
Charpy notched impact strength, -30°C 6 / 6 kJ/m² ISO 179/1eA
Type of failure C / C - -
Puncture - maximum force, +23°C 4380 / - N ISO 6603-2
Puncture - maximum force, -30°C 5690 / - N ISO 6603-2
Puncture energy, +23°C 53 / - J ISO 6603-2
Puncture energy, -30°C 60 / - J ISO 6603-2
Thermal propertiesdry / condUnitTest Standard
ISO Data
Melting temperature, 10°C/min 215 / * °C ISO 11357-1/-3
Glass transition temperature, 10°C/min 45 / * °C ISO 11357-1/-2
Temp. of deflection under load, 1.80 MPa 65 / * °C ISO 75-1/-2
Temp. of deflection under load, 0.45 MPa 150 / * °C ISO 75-1/-2
Vicat softening temperature, B 180 / * °C ISO 306
Coeff. of linear therm. expansion, parallel 130 / * E-6/K ISO 11359-1/-2
Coeff. of linear therm. expansion, normal 120 / * E-6/K ISO 11359-1/-2
Burning Behav. at 1.5 mm nom. thickn. HB / * class IEC 60695-11-10
Thickness tested 1.6 / * mm -
Electrical propertiesdry / condUnitTest Standard
ISO Data
Relative permittivity, 100Hz 3.8 / 4.5 - IEC 62631-2-1
Relative permittivity, 1MHz 3.2 / 4.1 - IEC 62631-2-1
Dissipation factor, 100Hz 240 / 590 E-4 IEC 62631-2-1
Dissipation factor, 1MHz 290 / 510 E-4 IEC 62631-2-1
Volume resistivity >1E13 / 1E12 Ohm*m IEC 62631-3-1
Electric strength 28 / 27 kV/mm IEC 60243-1
Other propertiesdry / condUnitTest Standard
Water absorption 2.7 / * % Sim. to ISO 62
Humidity absorption 1 / * % Sim. to ISO 62
Density 1060 / - kg/m³ ISO 1183
Diagrams
Viscosity-shear rate , VESTAMID® D16, PA612, Evonik
Shearstress-shear rate , VESTAMID® D16, PA612, Evonik
Dynamic Shear modulus-temperature , VESTAMID® D16 (dry), PA612, Evonik
Stress-strain , VESTAMID® D16 (dry), PA612, Evonik
Secant modulus-strain , VESTAMID® D16 (dry), PA612, Evonik
Stress-strain (isochronous) 23°C, VESTAMID® D16 (cond.), PA612, Evonik
Creep modulus-time 23°C, VESTAMID® D16 (cond.), PA612, Evonik
Creep curve 23°C, VESTAMID® D16 (cond.), PA612, Evonik
Specific volume-temperature (pvT) , VESTAMID® D16, PA612, Evonik
Characteristics
Processing
Injection Molding, Profile Extrusion, Other Extrusion
Delivery form
Pellets
Applications
Monofilament
Regional Availability
Disclaimer
Copyright Altair Engineering GmbH. Altair Engineering GmbH assumes no liability for the system to be free of errors. The user takes sole responsibility for the use of this data under the exclusion of every liability from Altair Engineering GmbH; this is especially valid for claims of compensation resulting from consequential damages. Altair explicitly points out that any decision about the application of materials must be double checked with the producer of this material. This includes all contents of this system. Copyright laws are applicable for the content of this system.
Created: Source: www.materialdatacenter.com


Material Data Center is provided by M-Base Engineering + Software GmbH. M-Base Engineering + Software GmbH assumes no liability for the system to be free of errors. Any decision about the application of materials must be double checked with the producer of this material.

Additional information about this material, like producer contact address, etc. can be found at www.materialdatacenter.com. For access to this extra information a registration is requested. Free online registration is available.