Complete Set of CAMPUS® Data, ASTM Data, Biopolymer Database, Application Database, Tradename Database, Literature Database, Toolbox.

Material datasheets available free. Online registration at: www.materialdatacenter.com

Material Data Center is a leading international information system for the plastics industry. Material Data Center offers a comprehensive plastics database, calculation tools, CAE interfaces, a literature database and an application database. For more information about Material Data Center visit www.materialdatacenter.com.

This is the free Material Data Center Datasheet of VESTAMID® DX9330 - PA612 - Evonik Operations GmbH

Material Data Center offers the following functions for VESTAMID® DX9330:
unit conversion, PDF datasheet print, comparison with other plastics, snap fit calculation, beam deflection calculation, CAE Interfaces

Check here, which other Vestamid datasheets, application examples or technical articles are available in Material Data Center

Use the following short links to get directly to the properties of interest in this datasheet:
Any use of this information falls under the rules of our disclaimer.
Product Texts
Medium viscosity polyamide 612 resin

VESTAMID® DX9330 NC is a PA 612 base polymer without any stabilizers and other additives.

VESTAMID® DX9330 NC is suitable for both extrusion as well as injection molding. Usually VESTAMID® DX9330 NC is only used in special cases when additives are not preferable, or processing aids are not necessary, e.g. filament extrusion.

Based on the perfect balance of amino and carboxyl end groups this material is easy to process and to dye. The typical characteristics of PA 612 are moderate water absorption, good dimensional stability and almost unchanged properties at varying ambient humidity.
  
VESTAMID® DX9330 NC is supplied as cylindrical granules, ready for processing, in moisture-proof bags. The processing temperature should be within a range of 250°C to 290°C.

Pigmentation may affect values.

Inside the original and undamaged packaging, the product has a shelf life of at least 2 years when stored in dry rooms at temperatures not exceeding 30°C.

The results shown have been generated from a low number of production lots. Therefore, they are preliminary and not yet the result of a statistical evaluation. Therefore they must not be used to establish specifications. 

For information about processing of VESTAMID®, please follow the general commendations about “Processing of VESTAMID® compounds”. 

FOR FURTHER INFORMATION PLEASE CONTACT US AT EVONIK-HP@EVONIK.COM OR VISIT OUR PRODUCT AT  WWW.VESTAMID.COM
Processing/Physical Characteristicsdry / condUnitTest Standard
ISO Data
Melt volume-flow rate, MVR 69 / * cm³/10min ISO 1133
Temperature 240 / * °C -
Load 10 / * kg -
Molding shrinkage, parallel 1.4 / * % ISO 294-4, 2577
Molding shrinkage, normal 1.4 / * % ISO 294-4, 2577
Mechanical propertiesdry / condUnitTest Standard
ISO Data
Tensile Modulus 2196 / - MPa ISO 527
Yield stress 58 / - MPa ISO 527
Yield strain 4 / - % ISO 527
Nominal strain at break >50 / - % ISO 527
Charpy impact strength, +23°C N / - kJ/m² ISO 179/1eU
Charpy impact strength, -30°C N / - kJ/m² ISO 179/1eU
Charpy notched impact strength, +23°C 4.5 / - kJ/m² ISO 179/1eA
Type of failure C / - - -
Charpy notched impact strength, -30°C 4.5 / - kJ/m² ISO 179/1eA
Type of failure C / - - -
Thermal propertiesdry / condUnitTest Standard
ISO Data
Melting temperature, 10°C/min 215 / * °C ISO 11357-1/-3
Glass transition temperature, 10°C/min 44 / * °C ISO 11357-1/-2
Temp. of deflection under load, 1.80 MPa 58 / * °C ISO 75-1/-2
Temp. of deflection under load, 0.45 MPa 149 / * °C ISO 75-1/-2
Vicat softening temperature, B 180 / * °C ISO 306
Other propertiesdry / condUnitTest Standard
Water absorption 2.8 / * % Sim. to ISO 62
Humidity absorption 1.4 / * % Sim. to ISO 62
Density 1060 / - kg/m³ ISO 1183
Characteristics
Processing
Injection Molding, Other Extrusion
Delivery form
Pellets, Natural Color
Applications
Filament for 3D Printing
Regional Availability
Disclaimer
Copyright Altair Engineering GmbH. Altair Engineering GmbH assumes no liability for the system to be free of errors. The user takes sole responsibility for the use of this data under the exclusion of every liability from Altair Engineering GmbH; this is especially valid for claims of compensation resulting from consequential damages. Altair explicitly points out that any decision about the application of materials must be double checked with the producer of this material. This includes all contents of this system. Copyright laws are applicable for the content of this system.
Created: Source: www.materialdatacenter.com


Material Data Center is provided by M-Base Engineering + Software GmbH. M-Base Engineering + Software GmbH assumes no liability for the system to be free of errors. Any decision about the application of materials must be double checked with the producer of this material.

Additional information about this material, like producer contact address, etc. can be found at www.materialdatacenter.com. For access to this extra information a registration is requested. Free online registration is available.