Complete Set of CAMPUS® Data, ASTM Data, Biopolymer Database, Application Database, Tradename Database, Literature Database, Toolbox.

Material datasheets available free. Online registration at: www.materialdatacenter.com

Material Data Center is a leading international information system for the plastics industry. Material Data Center offers a comprehensive plastics database, calculation tools, CAE interfaces, a literature database and an application database. For more information about Material Data Center visit www.materialdatacenter.com.

This is the free Material Data Center Datasheet of Makrolon® Ai2215 EL - PC - Covestro Deutschland AG

Material Data Center offers the following functions for Makrolon® Ai2215 EL:
unit conversion, PDF datasheet print, comparison with other plastics, snap fit calculation, beam deflection calculation, CAE Interfaces

Check here, which other Makrolon datasheets, application examples or technical articles are available in Material Data Center

Use the following short links to get directly to the properties of interest in this datasheet:
Any use of this information falls under the rules of our disclaimer.
Processing/Physical CharacteristicsValueUnitTest Standard
ISO Data
Melt volume-flow rate, MVR 34 cm³/10min ISO 1133
Temperature 300 °C -
Load 1.2 kg -
Molding shrinkage, parallel 0.7 % ISO 294-4, 2577
Molding shrinkage, normal 0.7 % ISO 294-4, 2577
Mechanical propertiesValueUnitTest Standard
ISO Data
Tensile Modulus 2200 MPa ISO 527
Yield stress 63 MPa ISO 527
Yield strain 6 % ISO 527
Nominal strain at break >50 % ISO 527
Stress at break 60 MPa ISO 527
Strain at break 125 % ISO 527
Charpy impact strength, -30°C N kJ/m² ISO 179/1eU
Charpy notched impact strength, +23°C, 3mm 60 kJ/m² ISO 179/1eA
Type of failure P - -
Charpy notched impact strength, -30°C, 3mm 15 kJ/m² ISO 179/1eA
Type of failure C - -
Izod notched impact strength, +23°C 55[1] kJ/m² ISO 180/1A
Izod notched impact strength 13[1] kJ/m² ISO 180/1A
Temperature -20 °C -
Puncture - maximum force, +23°C 4900 N ISO 6603-2
Puncture - maximum force, -30°C 5900 N ISO 6603-2
Puncture energy, +23°C 50 J ISO 6603-2
Puncture energy, -30°C 55 J ISO 6603-2
1: 3 mm
Thermal propertiesValueUnitTest Standard
ISO Data
Glass transition temperature, 10°C/min 145 °C ISO 11357-1/-2
Temp. of deflection under load, 1.80 MPa 125 °C ISO 75-1/-2
Temp. of deflection under load, 0.45 MPa 138 °C ISO 75-1/-2
Vicat softening temperature, B 145 °C ISO 306
Coeff. of linear therm. expansion, parallel 67 E-6/K ISO 11359-1/-2
Coeff. of linear therm. expansion, normal 67 E-6/K ISO 11359-1/-2
Oxygen index 28 % ISO 4589-1/-2
Optical propertiesValueUnitTest Standard
ISO Data
Haze 13[2] - ISO 14782
Luminous transmittance 85[2] % ISO 13468-1, -2
2: 4 mm
Other propertiesValueUnitTest Standard
Water absorption 0.3 % Sim. to ISO 62
Humidity absorption 0.12 % Sim. to ISO 62
Density 1190 kg/m³ ISO 1183
Bulk density 660 kg/m³ -
Test specimen productionValueUnitTest Standard
ISO Data
Injection Molding, melt temperature 280 °C ISO 294
Injection Molding, mold temperature 80 °C ISO 294
Injection Molding, injection velocity 200 mm/s ISO 294
Processing Recommendation Injection MoldingValueUnitTest Standard
Pre-drying - Temperature 120 °C -
Pre-drying - Time 2 - 3 h -
Processing humidity ≤0.02 % -
Melt temperature 250 - 300 °C -
Mold temperature 80 - 120 °C -
Zone 1 230 - 240 °C -
Zone 2 250 - 260 °C -
Zone 3 260 - 270 °C -
Nozzle temperature 260 - 270 °C -
Back pressure 5 - 15 MPa -
Characteristics
Processing
Injection Molding
Delivery form
Pellets
Additives
Release agent
Special Characteristics
Transparent
Features
Light Guiding
Applications
Automotive
Regional Availability
North America, Europe, Asia Pacific, South and Central America, Near East/Africa
Disclaimer
Copyright Altair Engineering GmbH. Altair Engineering GmbH assumes no liability for the system to be free of errors. The user takes sole responsibility for the use of this data under the exclusion of every liability from Altair Engineering GmbH; this is especially valid for claims of compensation resulting from consequential damages. Altair explicitly points out that any decision about the application of materials must be double checked with the producer of this material. This includes all contents of this system. Copyright laws are applicable for the content of this system.
Created: Source: www.materialdatacenter.com


Material Data Center is provided by M-Base Engineering + Software GmbH. M-Base Engineering + Software GmbH assumes no liability for the system to be free of errors. Any decision about the application of materials must be double checked with the producer of this material.

Additional information about this material, like producer contact address, etc. can be found at www.materialdatacenter.com. For access to this extra information a registration is requested. Free online registration is available.