Complete Set of CAMPUS® Data, ASTM Data, Biopolymer Database, Application Database, Tradename Database, Literature Database, Toolbox.

Material datasheets available free. Online registration at: www.materialdatacenter.com

Material Data Center is a leading international information system for the plastics industry. Material Data Center offers a comprehensive plastics database, calculation tools, CAE interfaces, a literature database and an application database. For more information about Material Data Center visit www.materialdatacenter.com.

This is the free Material Data Center Datasheet of RTP 899 X 120422 A - POM - RTP Company

Material Data Center offers the following functions for RTP 899 X 120422 A:
unit conversion, PDF datasheet print, comparison with other plastics

Check here, which other RTP datasheets, application examples or technical articles are available in Material Data Center

Use the following short links to get directly to the properties of interest in this datasheet:
Any use of this information falls under the rules of our disclaimer.
Processing/Physical CharacteristicsValueUnitTest Standard
ASTM Data
Mold Shrinkage, MD 0.02 mm/mm ASTM D 955
Mechanical propertiesValueUnitTest Standard
ASTM Data
Tensile Modulus 2344 MPa ASTM D 638
Tensile Strength 60 MPa ASTM D 638
Flexural Modulus 2620 MPa ASTM D 790
Flexural Strength 85.5 MPa ASTM D 790
Izod Impact notched, 1/8 in 48 J/m ASTM D 256
Electrical propertiesValueUnitTest Standard
ASTM Data
Surface Resistivity 1E7 Ohm ASTM D 257
Volume Resistivity 1000 Ohm*cm ASTM D 257
Other propertiesValueUnitTest Standard
Density 1420 kg/m³ ASTM D 792
Moisture Content 0.1 % -
Processing Recommendation Injection MoldingValueUnitTest Standard
Pre-drying - Temperature 82.2 °C -
Pre-drying - Time 2 h -
Melt temperature 182 - 204 °C -
Mold temperature 71.1 - 93.3 °C -
Injection pressure 68.9 - 103 MPa -
Characteristics
Processing
Injection Molding
Regional Availability
North America, Europe, Asia Pacific
Disclaimer
Copyright Altair Engineering GmbH. Altair Engineering GmbH assumes no liability for the system to be free of errors. The user takes sole responsibility for the use of this data under the exclusion of every liability from Altair Engineering GmbH; this is especially valid for claims of compensation resulting from consequential damages. Altair explicitly points out that any decision about the application of materials must be double checked with the producer of this material. This includes all contents of this system. Copyright laws are applicable for the content of this system.
Created: Source: www.materialdatacenter.com


Material Data Center is provided by M-Base Engineering + Software GmbH. M-Base Engineering + Software GmbH assumes no liability for the system to be free of errors. Any decision about the application of materials must be double checked with the producer of this material.

Additional information about this material, like producer contact address, etc. can be found at www.materialdatacenter.com. For access to this extra information a registration is requested. Free online registration is available.