Material Data Center is a leading international information system for the plastics industry. Material Data Center offers a comprehensive plastics database, calculation tools, CAE interfaces, a literature database and an application database. For more information about Material Data Center visit www.materialdatacenter.com.

This is the free Material Data Center Datasheet of VESTAKEEP® 4000 GF30 - PEEK-GF30 - Evonik Operations GmbH

Material Data Center offers the following functions for VESTAKEEP® 4000 GF30:
unit conversion, PDF datasheet print, comparison with other plastics, snap fit calculation, beam deflection calculation, CAE Interfaces

Check here, which other Vestakeep datasheets, application examples or technical articles are available in Material Data Center

Use the following short links to get directly to the properties of interest in this datasheet:
Any use of this information falls under the rules of our disclaimer.
Product Texts
Glass fiber-reinforced (30%) polyether ether ketone

VESTAKEEP® 4000 GF30 is a glass fiber-re­inforced (30%) polyether ether ketone for injection molding.

The semi-crystalline polymer features superior mechanical, thermal, and chemical resistance. Parts made from VESTAKEEP® 4000 GF30 are of low flammability.

VESTAKEEP® 4000 GF30 can be processed on common injection molding machines for thermoplastics.

We recommend a melt temperature of 380°C to 400°C during the injection molding process. The mold temperature should be within a range of 160°C to 200°C, preferably 180°C.

VESTAKEEP® 4000 GF30 is supplied as cylindrical pellets in 25kg boxes with moisture-proof polyethylene liners.

Inside the original and undamaged packaging, the product has a shelf life of at least 2 years when stored in dry rooms at temperatures not exceeding 30°C.

Pigmentation may affect the values.

For guidance processing of VESTAKEEP® 4000 GF30 please follow the general recommendations in our brochure “VESTAKEEP® PEEK Processing Guidelines“.

FOR FURTHER INFORMATION PLEASE CONTACT US AT EVONIK-HP@EVONIK.COM OR VISIT OUR PRODUCT AT  WWW.INDUSTRIAL.VESTAKEEP.COM
Processing/Physical CharacteristicsValueUnitTest Standard
ISO Data
Melt volume-flow rate, MVR 32 cm³/10min ISO 1133
Temperature 400 °C -
Load 21.6 kg -
Molding shrinkage, parallel 0.3 % ISO 294-4, 2577
Molding shrinkage, normal 0.7 % ISO 294-4, 2577
Mechanical propertiesValueUnitTest Standard
ISO Data
Tensile Modulus 11000 MPa ISO 527
Stress at break 160 MPa ISO 527
Strain at break 2 % ISO 527
Charpy impact strength, +23°C 70 kJ/m² ISO 179/1eU
Type of failure C - -
Charpy impact strength, -30°C 75 kJ/m² ISO 179/1eU
Type of failure C - -
Charpy notched impact strength, +23°C 11 kJ/m² ISO 179/1eA
Type of failure C - -
Charpy notched impact strength, -30°C 9 kJ/m² ISO 179/1eA
Type of failure C - -
Thermal propertiesValueUnitTest Standard
ISO Data
Melting temperature, 10°C/min 340 °C ISO 11357-1/-3
Temp. of deflection under load, 1.80 MPa 312 °C ISO 75-1/-2
Temp. of deflection under load, 0.45 MPa 335 °C ISO 75-1/-2
Vicat softening temperature, B 335 °C ISO 306
Coeff. of linear therm. expansion, parallel 30 E-6/K ISO 11359-1/-2
Burning Behav. at 1.5 mm nom. thickn. V-0 class IEC 60695-11-10
Thickness tested 1.6 mm -
Oxygen index 45 % ISO 4589-1/-2
Electrical propertiesValueUnitTest Standard
ISO Data
Relative permittivity, 1MHz 3.3 - IEC 62631-2-1
Dissipation factor, 1MHz 40 E-4 IEC 62631-2-1
Volume resistivity >1E13 Ohm*m IEC 62631-3-1
Surface resistivity 1E15 Ohm IEC 62631-3-2
Comparative tracking index 200 - IEC 60112
Other propertiesValueUnitTest Standard
Water absorption 0.4 % Sim. to ISO 62
Density 1500 kg/m³ ISO 1183
Diagrams
Tensile modulus-temperature , VESTAKEEP® 4000 GF30, PEEK-GF30, Evonik
Characteristics
Processing
Injection Molding, Other Extrusion
Delivery form
Pellets
Regional Availability
North America, Europe, Asia Pacific, South and Central America, Near East/Africa
Disclaimer
Copyright Altair Engineering GmbH. Altair Engineering GmbH assumes no liability for the system to be free of errors. The user takes sole responsibility for the use of this data under the exclusion of every liability from Altair Engineering GmbH; this is especially valid for claims of compensation resulting from consequential damages. Altair explicitly points out that any decision about the application of materials must be double checked with the producer of this material. This includes all contents of this system. Copyright laws are applicable for the content of this system.