Complete Set of CAMPUS® Data, ASTM Data, Biopolymer Database, Application Database, Tradename Database, Literature Database, Toolbox.

Material datasheets available free. Online registration at: www.materialdatacenter.com

Material Data Center is a leading international information system for the plastics industry. Material Data Center offers a comprehensive plastics database, calculation tools, CAE interfaces, a literature database and an application database. For more information about Material Data Center visit www.materialdatacenter.com.

This is the free Material Data Center Datasheet of LEONA™ 1402S - PA66 - Asahi Kasei

Material Data Center offers the following functions for LEONA™ 1402S:
unit conversion, PDF datasheet print, comparison with other plastics, snap fit calculation, beam deflection calculation, CAE Interfaces

Check here, which other Leona datasheets, application examples or technical articles are available in Material Data Center

Use the following short links to get directly to the properties of interest in this datasheet:
Any use of this information falls under the rules of our disclaimer.
Propiedades mecánicasSeco / CondUnidadesMétodo de ensayo
ISO Data
Módulo de tracción 3000 / 1200 MPa ISO 527
Esfuerzo de fluencia 82 / 52 MPa ISO 527
Alarg. en límite elástico 4 / 24 % ISO 527
Módulo de flexión, 23°C 2700 / 1100 MPa ISO 178
Resistencia a la flexión 113 / 42 MPa ISO 178
Resistencia al impacto Charpy, +23°C N / N kJ/m² ISO 179/1eU
Resistencia al impacto Charpy c/entalla, +23°C 6 / 15 kJ/m² ISO 179/1eA
Dureza Rockwell R 120 - ISO 2039-2
ASTM Data
Esfuerzo de tracción 79 / 57 MPa ASTM D 638
Alargamiento a la rotura 50 / 250 % ASTM D 638
Módulo de flexión 2800 / 1200 MPa ASTM D 790
Resistencia a la flexión 118 / 54 MPa ASTM D 790
Dureza Rockwell M 80 / M 55 - ASTM D 785
Resistencia a la abrasión (Taber) 7 mg/1000 cycles ASTM D 1044
Resistencia al impacto Izod con entalla, 1/8 in 39 / 147 J/m ASTM D 256
Propiedades térmicasSeco / CondUnidadesMétodo de ensayo
ISO Data
Estabilidad al calor, 1.80 MPa 70 / * °C ISO 75-1/-2
Estabilidad al calor, 0.45 MPa 190 / * °C ISO 75-1/-2
Combustibilidad a espesor h V-2 / * class IEC 60695-11-10
Espesores de probeta 0.8 / * mm -
Yellow Card disponible sí / * - -
Glow Wire Flammability Index (GWFI) 960 °C IEC 60695-2-12
GWFI - thickness tested (1) 3 mm -
ASTM Data
Combustibilidad UL 94 V-2 - UL 94
Espesores de probeta 0.75 mm -
Coeficiente de dilatación térmica, long. 80 E-6/K ASTM D 696
Estabilidad al calor @ 66 psi 230 °C ASTM D 648
Estabilidad al calor @ 264 psi 70 °C ASTM D 648
Índice de oxigeno límite 26 % ASTM D 2863
Propiedades eléctricasSeco / CondUnidadesMétodo de ensayo
ISO Data
Resistividad volumétrica específica 1E12 / - Ohm*m IEC 62631-3-1
Resistividad superficial específica * / 1E13 Ohm IEC 62631-3-2
Resistencia dieléctrica 20 / - kV/mm IEC 60243-1
Indice comparativo de linea de fuga 525 / - - IEC 60112
ASTM Data
Resistencia dieléctrica, tiempo corto 20 / - kV/mm ASTM D 149
Resistividad volumétrica 1E14 / - Ohm*cm ASTM D 257
Otras propiedadesSeco / CondUnidadesMétodo de ensayo
Absorción de humedad 2.5 / * % Sim. to ISO 62
Densidad 1140 / - kg/m³ ISO 1183
Densidad 1140 kg/m³ ASTM D 792
Recomendación para procesamiento Moldeo por inyecciónValorUnidadesMétodo de ensayo
Temperatura de pre-secado 80 - 90 °C -
Tiempo de pre-secado 2 - 3 h -
Temperatura de la masa 270 - 290 °C -
Temperatura del molde 75 - 85 °C -
Características
Procesamiento y forma de entrega
Moldeo por inyección, Extrusión de cable
Forma de suministro
Sémola
Características especiales
Estable contra el calor
Applicaciones
Automotriz
Disponibilidad regional
Norteamérica, Europa, Asia Pacifico, América del Sur y Centroaméric, Próximo Oriente/Africa
Disclaimer
Copyright Altair Engineering GmbH. Altair Engineering GmbH assumes no liability for the system to be free of errors. The user takes sole responsibility for the use of this data under the exclusion of every liability from Altair Engineering GmbH; this is especially valid for claims of compensation resulting from consequential damages. Altair explicitly points out that any decision about the application of materials must be double checked with the producer of this material. This includes all contents of this system. Copyright laws are applicable for the content of this system.
Created: Source: www.materialdatacenter.com


Material Data Center is provided by M-Base Engineering + Software GmbH. M-Base Engineering + Software GmbH assumes no liability for the system to be free of errors. Any decision about the application of materials must be double checked with the producer of this material.

Additional information about this material, like producer contact address, etc. can be found at www.materialdatacenter.com. For access to this extra information a registration is requested. Free online registration is available.