Complete Set of CAMPUS® Data, ASTM Data, Biopolymer Database, Application Database, Tradename Database, Literature Database, Toolbox.

Material datasheets available free. Online registration at: www.materialdatacenter.com

Material Data Center is a leading international information system for the plastics industry. Material Data Center offers a comprehensive plastics database, calculation tools, CAE interfaces, a literature database and an application database. For more information about Material Data Center visit www.materialdatacenter.com.

This is the free Material Data Center Datasheet of Ultraform® N2320 003 PRO AT - POM - BASF

Material Data Center offers the following functions for Ultraform® N2320 003 PRO AT:
unit conversion, PDF datasheet print, comparison with other plastics, snap fit calculation, beam deflection calculation, parameters for material models, CAE Interfaces

Check here, which other Ultraform datasheets, application examples or technical articles are available in Material Data Center

Use the following short links to get directly to the properties of interest in this datasheet:
Any use of this information falls under the rules of our disclaimer.
Texto del producto
Rapidly solidifying standard grade for injection molding.

Ultraform® PRO offers a comprehensive service package, which supports customers in product development for the medical technology market.

Ultraform® PRO complies with the basic requirements of Pharmacopoeia and Biocompatibility-Tests in Europe, United States and Japan respectively as specified below. However, the biocompatibility tests were recorded on tests specimens of Ultraform PRO to show compatibility and potential suitability of the material in general. The biocompatibility-tests and the other tests listed below are not part of any continuous production control.

European Pharmacopoeia, Japanese Pharmacopoeia:
The composition of the product complies with the basic requirements of the European Pharmacopoeia 8th Edition, Chap.
3.2.2. "Plastic Containers and Closures for Pharmaceutical Use" and with the basic requirements of the Japanese Pharmacopoeia,16th Edition, General Information, “17. Plastic Containers for Pharmaceutical Products”. However, suitability for the end application concerned including observation of given limitations and toxicological thresholds have to be ensured on the final article by the producer.

US Pharmacopoeia: Biological Reactivity Tests, USP Plastic Class VI (USP VI)

ISO 10993-5: Biological Evaluation of Medical Devices Part 5: Test for Cytotoxicity

DMF: A Drug Master File (DMF) has been registered at FDA for Ultraform® PRO.

Food Contact: Ultraform® PRO is in compliance with multiple regional food contact regulations, especially for Europe and United States.

Additional compliances may also be available. Please contact your local representative or the Ultraplaste Infopoint (E-Mail: ultraplaste.infopoint@basf.com, Telefon: 49 621-60-78780, Fax: 49 621-60-78730).

For notice:
However, BASF has not designed or tested its plastics with respect to all of the special requirements related to their use in medical devices (defined in risk classes I to III according to the European and US Medical Device legislation) and pharmaceutical applications. Therefore BASF makes no warranties, express or implied, concerning the suitability of any BASF plastics for use in any medical device and pharmaceutical applications.

Abbreviated designation according to ISO 1043-1: POM
Designation according to ISO 29988-POM-K,,M-GNR,4-2
Caracteristicas de procesamiento y fisicasValorUnidadesMétodo de ensayo
ISO Data
Indice de fluidez volumétrico, MVR 7.5 cm³/10min ISO 1133
Temperatura 190 °C -
Carga 2.16 kg -
Contracción posterior al moldeo, paralelo 2.1 % ISO 294-4, 2577
Contracción posterior al moldeo, normal 2.1 % ISO 294-4, 2577
Propiedades mecánicasValorUnidadesMétodo de ensayo
ISO Data
Módulo de tracción 2700 MPa ISO 527
Esfuerzo de fluencia 64 MPa ISO 527
Alarg. en límite elástico 10.7 % ISO 527
Alarg. nominal a rotura 32 % ISO 527
Módulo de plastodeformación, 1h 1800 MPa ISO 899-1
Módulo de plastodeformación, 1000h 1400 MPa ISO 899-1
Resistencia al impacto Charpy, +23°C 270 kJ/m² ISO 179/1eU
Resistencia al impacto Charpy, -30°C 250 kJ/m² ISO 179/1eU
Resistencia al impacto Charpy c/entalla, +23°C 6.5 kJ/m² ISO 179/1eA
Resistencia al impacto Charpy c/entalla, -30°C 5.5 kJ/m² ISO 179/1eA
Propiedades térmicasValorUnidadesMétodo de ensayo
ISO Data
Temperatura de fusión, 10°C/min 166 °C ISO 11357-1/-3
Estabilidad al calor, 1.80 MPa 95 °C ISO 75-1/-2
Estabilidad al calor, 0.45 MPa 156 °C ISO 75-1/-2
Temp. reblandecimiento Vicat, B 150 °C ISO 306
Coef.de expansión térmica lineal, paralelo 110 E-6/K ISO 11359-1/-2
Combustibilidad a 1.5mm esp. nom. HB class IEC 60695-11-10
Espesores de probeta 1.6 mm -
Yellow Card disponible - -
Combustibilidad a espesor h HB class IEC 60695-11-10
Espesores de probeta 0.8 mm -
Yellow Card disponible - -
Combustibilidad según índice de oxigeno 15 % ISO 4589-1/-2
Propiedades eléctricasValorUnidadesMétodo de ensayo
ISO Data
Constante dieléctrica, 100Hz 3.8 - IEC 62631-2-1
Constante dieléctrica, 1MHz 3.8 - IEC 62631-2-1
Factor de pérdidas dieléctricas, 100Hz 10 E-4 IEC 62631-2-1
Factor de pérdidas dieléctricas, 1MHz 50 E-4 IEC 62631-2-1
Resistividad volumétrica específica 1E11 Ohm*m IEC 62631-3-1
Resistividad superficial específica 1E13 Ohm IEC 62631-3-2
Resistencia dieléctrica 40 kV/mm IEC 60243-1
Indice comparativo de linea de fuga 600 - IEC 60112
Otras propiedadesValorUnidadesMétodo de ensayo
Absorción de agua 0.9 % Sim. to ISO 62
Absorción de humedad 0.2 % Sim. to ISO 62
Densidad 1410 kg/m³ ISO 1183
Recomendación para procesamiento Moldeo por inyecciónValorUnidadesMétodo de ensayo
Temperatura de pre-secado 100 °C -
Tiempo de pre-secado 3 h -
Humedad de procesamiento ≤0.2 % -
Temperatura de la masa 190 - 230 °C -
Temperatura del molde 60 - 120 °C -
Funciones
Esfuerzo-alargamiento , Ultraform® N2320 003 PRO AT, POM, BASF
Módulo secante-alargamiento , Ultraform® N2320 003 PRO AT, POM, BASF
Volumen especifico-temperatura (pvT) , Ultraform® N2320 003 PRO AT, POM, BASF
Características
Procesamiento y forma de entrega
Moldeo por inyección
Forma de suministro
Sémola
Aditivos
Desmoldeante
Certifications
Contacto con alimentos, Grado médico, Biocompatibility ISO 10993, USP Class VI, Drug Master File
Applicaciones
Médico
Disponibilidad regional
Demás información
Moldeo por inyección
PREPROCESSING
Pre/Post-processing, max. allowed water content: .2 %
Pre/Post-processing, Pre-drying, Temperature: 100 °C
Pre/Post-processing, Pre-drying, Time: 3 h

PROCESSING
injection molding, Melt temperature, range: 190 - 230 °C
injection molding, Melt temperature, recommended: 200 °C
injection molding, Mold temperature, range: 60 - 120 °C
injection molding, Mold temperature, recommended: 90 °C
injection molding, Dwell time, thermoplastics: 10 min

Processing

Usual single-flighted three-section screws with an effective screw length of at least 15 D, better 20 - 23 D are suitable for the injection molding of Ultraform.

Pretreatment

Granules or pellets in original packaging can be processed without any special pretreatment. Granules or pellets which have become moist due to prolonged or incorrect storage (e.g. by formation of condensed water) must be dried in dehumidifying or recirculating air dryers for approx. 3 hours at about 100 - 110 °C. The moisture content should not exceed 0.2 %.


Postprocessing

If parts were produced at a comparatively low mold temperature (e.g. in order to obtain short cycle times) and must not change their geometry in use thermal postprocessing inducing dimensional changes by postcrystallization may be necessary. In such cases parts should be stored in an oven with recirculated air at temperatures of 100 - 130 °C until dimensions don't change significantly any further. The time needed for this has to be determined experimentally.
Disclaimer
Copyright Altair Engineering GmbH. Altair Engineering GmbH assumes no liability for the system to be free of errors. The user takes sole responsibility for the use of this data under the exclusion of every liability from Altair Engineering GmbH; this is especially valid for claims of compensation resulting from consequential damages. Altair explicitly points out that any decision about the application of materials must be double checked with the producer of this material. This includes all contents of this system. Copyright laws are applicable for the content of this system.
Created: Source: www.materialdatacenter.com


Material Data Center is provided by M-Base Engineering + Software GmbH. M-Base Engineering + Software GmbH assumes no liability for the system to be free of errors. Any decision about the application of materials must be double checked with the producer of this material.

Additional information about this material, like producer contact address, etc. can be found at www.materialdatacenter.com. For access to this extra information a registration is requested. Free online registration is available.