Complete Set of CAMPUS® Data, ASTM Data, Biopolymer Database, Application Database, Tradename Database, Literature Database, Toolbox.

Material datasheets available free. Online registration at: www.materialdatacenter.com

Material Data Center is a leading international information system for the plastics industry. Material Data Center offers a comprehensive plastics database, calculation tools, CAE interfaces, a literature database and an application database. For more information about Material Data Center visit www.materialdatacenter.com.

This is the free Material Data Center Datasheet of VECTRA® E150i - LCP-GF50 - Celanese

Material Data Center offers the following functions for VECTRA® E150i:
unit conversion, PDF datasheet print, comparison with other plastics, snap fit calculation, beam deflection calculation, CAE Interfaces

Check here, which other Vectra datasheets, application examples or technical articles are available in Material Data Center

Use the following short links to get directly to the properties of interest in this datasheet:
Any use of this information falls under the rules of our disclaimer.
Texto del producto
Easy flowing grade with very good heat resistance, and mechanical properties. May reduce warpage in some parts compared to E130i. 50% glass reinforced. Chemical abbreviation according to ISO 1043-1 : LCP Inherently flame retardant FDA compliant UL-Listing V-0 in natural and black at 0.43mm thickness per UL 94 flame testing. Relative-Temperature-Index (RTI) according to UL 746B: electricals 240°C, mechanicals 240°C at 0.75mm. UL = Underwriters Laboratories (USA)

Flammability @1.6mm nom. thickn.V-0-
Flammability at thickness h (0.43 mm)V-0UL recognition (h)
Caracteristicas de procesamiento y fisicasValorUnidadesMétodo de ensayo
ISO Data
Contracción posterior al moldeo, paralelo 0.2 % ISO 294-4, 2577
Contracción posterior al moldeo, normal 0.5 % ISO 294-4, 2577
Propiedades mecánicasValorUnidadesMétodo de ensayo
ISO Data
Módulo de tracción 20000 MPa ISO 527
Resistencia a la tracción 130 MPa ISO 527
Alargamiento a rotura 1 % ISO 527
Resistencia al impacto Charpy, +23°C 19 kJ/m² ISO 179/1eU
Resistencia al impacto Charpy c/entalla, +23°C 10 kJ/m² ISO 179/1eA
Propiedades térmicasValorUnidadesMétodo de ensayo
ISO Data
Temperatura de fusión, 10°C/min 335 °C ISO 11357-1/-3
Estabilidad al calor, 1.80 MPa 260 °C ISO 75-1/-2
Estabilidad al calor, 8.00 MPa 225 °C ISO 75-1/-2
Temp. reblandecimiento Vicat, B 200 °C ISO 306
Coef.de expansión térmica lineal, paralelo 6 E-6/K ISO 11359-1/-2
Coef.de expansión térmica lineal, normal 17 E-6/K ISO 11359-1/-2
Combustibilidad a 1.5mm esp. nom. V-0 class IEC 60695-11-10
Espesores de probeta 1.5 mm -
Combustibilidad a espesor h V-0 class IEC 60695-11-10
Espesores de probeta 0.4 mm -
Yellow Card disponible - -
Propiedades eléctricasValorUnidadesMétodo de ensayo
ISO Data
Constante dieléctrica, 1MHz 4.7 - IEC 62631-2-1
Factor de pérdidas dieléctricas, 1MHz 280 E-4 IEC 62631-2-1
Resistividad volumétrica específica 1E13 Ohm*m IEC 62631-3-1
Resistividad superficial específica 1E14 Ohm IEC 62631-3-2
Resistencia dieléctrica 28 kV/mm IEC 60243-1
Otras propiedadesValorUnidadesMétodo de ensayo
Absorción de humedad 0.006 % Sim. to ISO 62
Densidad 1810 kg/m³ ISO 1183
Funciones
Esfuerzo-alargamiento , VECTRA® E150i, LCP-GF50, Celanese
Módulo secante-alargamiento , VECTRA® E150i, LCP-GF50, Celanese
Características
Forma de suministro
Negro, Color natural
Características especiales
Resistencia mejorada al fuego, Estable contra el calor
Características
Baja deformación
Certifications
Contacto con alimentos, Aprobado por el FDA 21 CFR
Disponibilidad regional
Norteamérica, Europa, Asia Pacifico
Disclaimer
Copyright Altair Engineering GmbH. Altair Engineering GmbH assumes no liability for the system to be free of errors. The user takes sole responsibility for the use of this data under the exclusion of every liability from Altair Engineering GmbH; this is especially valid for claims of compensation resulting from consequential damages. Altair explicitly points out that any decision about the application of materials must be double checked with the producer of this material. This includes all contents of this system. Copyright laws are applicable for the content of this system.
Created: Source: www.materialdatacenter.com


Material Data Center is provided by M-Base Engineering + Software GmbH. M-Base Engineering + Software GmbH assumes no liability for the system to be free of errors. Any decision about the application of materials must be double checked with the producer of this material.

Additional information about this material, like producer contact address, etc. can be found at www.materialdatacenter.com. For access to this extra information a registration is requested. Free online registration is available.