Complete Set of CAMPUS® Data, ASTM Data, Biopolymer Database, Application Database, Tradename Database, Literature Database, Toolbox.

Material datasheets available free. Online registration at: www.materialdatacenter.com

Material Data Center is a leading international information system for the plastics industry. Material Data Center offers a comprehensive plastics database, calculation tools, CAE interfaces, a literature database and an application database. For more information about Material Data Center visit www.materialdatacenter.com.

This is the free Material Data Center Datasheet of VESTAMID® L2124 - PA12 - Evonik Operations GmbH

Material Data Center offers the following functions for VESTAMID® L2124:
unit conversion, PDF datasheet print, comparison with other plastics, snap fit calculation, beam deflection calculation, parameters for material models, CAE Interfaces

Check here, which other Vestamid datasheets, application examples or technical articles are available in Material Data Center

Use the following short links to get directly to the properties of interest in this datasheet:
Any use of this information falls under the rules of our disclaimer.
Texto del producto
High viscosity, plasticized, heat and light stabilized PA12 Compound for extrusion

VESTAMID® L2124 NC is a plasticized, heat- and light- stabilized polyamide 12 compound for the extrusion of flexible tubing and hoses especially for oil and petrochemical applications.

Tubing according to DIN 73 378, Type: PA 12-PHL.

VESTAMID® L2124 NC is characterized by a high melt viscosity and good dimensional control during pipe extrusion.

Properties of compounds based on PA12 vary little with changing humidity due to low moisture absorption. Parts made of this semi-crystalline material are characterized by exceptional impact strength, low coefficient of friction and good chemical resistance.

Pigmentation may affect values.

Inside the original and undamaged packaging, the product has a shelf life of at least 2 years when stored in dry rooms at temperatures not exceeding 30°C.

For information about processing of VESTAMID®, please follow the general commendations about “Processing of VESTAMID® compounds”. 

FOR FURTHER INFORMATION PLEASE CONTACT US AT EVONIK-HP@EVONIK.COM
OR VISIT OUR PRODUCT AT  WWW.VESTAMID.COM

Caracteristicas de procesamiento y fisicasSeco / CondUnidadesMétodo de ensayo
ISO Data
Indice de fluidez volumétrico, MVR 19 / * cm³/10min ISO 1133
Temperatura 275 / * °C -
Carga 5 / * kg -
Contracción posterior al moldeo, paralelo 0.7 / * % ISO 294-4, 2577
Contracción posterior al moldeo, normal 1.6 / * % ISO 294-4, 2577
Propiedades mecánicasSeco / CondUnidadesMétodo de ensayo
ISO Data
Módulo de tracción 400 / 350 MPa ISO 527
Esfuerzo de fluencia 26 / 22 MPa ISO 527
Alarg. en límite elástico 31 / 27 % ISO 527
Alarg. nominal a rotura >50 / >50 % ISO 527
Módulo de plastodeformación, 1h * / 350 MPa ISO 899-1
Módulo de plastodeformación, 1000h * / 270 MPa ISO 899-1
Resistencia al impacto Charpy, +23°C N / - kJ/m² ISO 179/1eU
Resistencia al impacto Charpy, -30°C N / N kJ/m² ISO 179/1eU
Resistencia al impacto Charpy c/entalla, +23°C 140 / N kJ/m² ISO 179/1eA
Resistencia al impacto Charpy c/entalla, -30°C 6 / 6 kJ/m² ISO 179/1eA
Type of failure C / C - -
Propiedades térmicasSeco / CondUnidadesMétodo de ensayo
ISO Data
Temperatura de fusión, 10°C/min 169 / * °C ISO 11357-1/-3
Estabilidad al calor, 1.80 MPa 45 / * °C ISO 75-1/-2
Estabilidad al calor, 0.45 MPa 98 / * °C ISO 75-1/-2
Temp. reblandecimiento Vicat, B 125 / * °C ISO 306
Coef.de expansión térmica lineal, paralelo 180 / * E-6/K ISO 11359-1/-2
Coef.de expansión térmica lineal, normal 170 / * E-6/K ISO 11359-1/-2
Combustibilidad a 1.5mm esp. nom. HB / * class IEC 60695-11-10
Espesores de probeta 1.6 / * mm -
Propiedades eléctricasSeco / CondUnidadesMétodo de ensayo
ISO Data
Constante dieléctrica, 100Hz 12 / 16 - IEC 62631-2-1
Constante dieléctrica, 1MHz 3.8 / 4.2 - IEC 62631-2-1
Factor de pérdidas dieléctricas, 100Hz 1600 / 1600 E-4 IEC 62631-2-1
Factor de pérdidas dieléctricas, 1MHz 1500 / 2000 E-4 IEC 62631-2-1
Resistividad volumétrica específica 1E10 / 2E9 Ohm*m IEC 62631-3-1
Resistividad superficial específica * / 1E12 Ohm IEC 62631-3-2
Resistencia dieléctrica 32 / 27 kV/mm IEC 60243-1
Indice comparativo de linea de fuga 600 / 600 - IEC 60112
Otras propiedadesSeco / CondUnidadesMétodo de ensayo
Absorción de agua 1.3 / * % Sim. to ISO 62
Absorción de humedad 0.5 / * % Sim. to ISO 62
Densidad 1030 / 1040 kg/m³ ISO 1183
Funciones
Viscosidad-velocidad de cizallamiento , VESTAMID® L2124, PA12, Evonik
Tensión de cizalla-velocidad de cizalla , VESTAMID® L2124, PA12, Evonik
Módulo de cizallamiento dinámico-temperatura , VESTAMID® L2124 (Seco), PA12, Evonik
Esfuerzo-alargamiento , VESTAMID® L2124 (Seco), PA12, Evonik
Módulo secante-alargamiento , VESTAMID® L2124 (Seco), PA12, Evonik
Módulo a tensión-temperatura , VESTAMID® L2124 (Seco), PA12, Evonik
Características
Procesamiento y forma de entrega
Moldeo por inyección, Extrusión de tubería, Extrusión de perfiles, Otros tipos de extrusión
Forma de suministro
Sémola, Color natural
Aditivos
Lubricante, Plastificante
Características especiales
Alto impacto o modificado al impacto, Estable a la luz, Estable contra rayos U.V./interperie, Estable contra el calor
Características
Grado tribológico
Resistencia quimica
Resistencia química general
Disponibilidad regional
Disclaimer
Copyright Altair Engineering GmbH. Altair Engineering GmbH assumes no liability for the system to be free of errors. The user takes sole responsibility for the use of this data under the exclusion of every liability from Altair Engineering GmbH; this is especially valid for claims of compensation resulting from consequential damages. Altair explicitly points out that any decision about the application of materials must be double checked with the producer of this material. This includes all contents of this system. Copyright laws are applicable for the content of this system.
Created: Source: www.materialdatacenter.com


Material Data Center is provided by M-Base Engineering + Software GmbH. M-Base Engineering + Software GmbH assumes no liability for the system to be free of errors. Any decision about the application of materials must be double checked with the producer of this material.

Additional information about this material, like producer contact address, etc. can be found at www.materialdatacenter.com. For access to this extra information a registration is requested. Free online registration is available.