Complete Set of CAMPUS® Data, ASTM Data, Biopolymer Database, Application Database, Tradename Database, Literature Database, Toolbox.

Material datasheets available free. Online registration at: www.materialdatacenter.com

Material Data Center is a leading international information system for the plastics industry. Material Data Center offers a comprehensive plastics database, calculation tools, CAE interfaces, a literature database and an application database. For more information about Material Data Center visit www.materialdatacenter.com.

This is the free Material Data Center Datasheet of Makrolon® 3638 - PC - Covestro Deutschland AG

Material Data Center offers the following functions for Makrolon® 3638:
unit conversion, PDF datasheet print, comparison with other plastics, snap fit calculation, beam deflection calculation, CAE Interfaces

Check here, which other Makrolon datasheets, application examples or technical articles are available in Material Data Center

Use the following short links to get directly to the properties of interest in this datasheet:
Any use of this information falls under the rules of our disclaimer.
Informations produit
  • MVR (300 °C/1.2 kg) 2.0 cm³/10 min
  • high viscosity
  • food contact quality
  • biocompatible according to many ISO 10993-1 test requirements
  • pharmaceutical applications
  • medical devices
Caractéristiques des transformations/physiquesValeurUnitéNorme du test
ISO Data
Indice de fluidité à chaud en volume, MVR 2 cm³/10min ISO 1133
Température 300 °C -
Charge 1.2 kg -
Indice de fluidité, MFI 2.5 g/10min ISO 1133
Température 300 °C -
Charge 1.2 kg -
Retrait au moulage, parallèle 0.8 % ISO 294-4, 2577
Retrait au moulage, perpendiculaire 0.8 % ISO 294-4, 2577
Propriétés mécaniquesValeurUnitéNorme du test
ISO Data
Module en traction 2300 MPa ISO 527
Contrainte d'écoulement 64 MPa ISO 527
Déformation au seuil d'écoulement 6.6 % ISO 527
Déformation nominale à la rupture >50 % ISO 527
Module de flexion, 23°C 2300 MPa ISO 178
Résistance à la flexion 94 MPa ISO 178
Résistance au choc Charpy, +23°C N kJ/m² ISO 179/1eU
Résistance au choc Charpy (entaillé), +23°C, 3mm 75 kJ/m² ISO 179/1eA
Type de défaillance P - -
Résistance au choc Charpy (entaillé), -30°C, 3mm 20 kJ/m² ISO 179/1eA
Type de défaillance C(P) - -
Résistance au choc Izod avec entaille, +23°C 65 kJ/m² ISO 180/1A
Résistance au choc Izod avec entaille 55 kJ/m² ISO 180/1A
Température -30 °C -
Perforation - force maximum, +23°C 5500 N ISO 6603-2
Perforation - force maximum, -30°C 6400 N ISO 6603-2
Perforation - Energie, +23°C 55 J ISO 6603-2
Perforation - Energie, -30°C 60 J ISO 6603-2
Ball indentation hardness 108 MPa ISO 2039-1
Propriétés thermiquesValeurUnitéNorme du test
ISO Data
Température de transition vitreuse, 10°C/min 152 °C ISO 11357-1/-2
Température de fléchissement s/chrg, 1.80 MPa 132 °C ISO 75-1/-2
Température de fléchissement s/chrg, 0.45 MPa 145 °C ISO 75-1/-2
Température de ramolliss. Vicat, B 150 °C ISO 306
Coeffic. de dilatation therm. linéique, parallèle 70 E-6/K ISO 11359-1/-2
Coeffic. de dilatation therm. linéique, perpend. 70 E-6/K ISO 11359-1/-2
Aptitude à l'allumage 26 % ISO 4589-1/-2
Propriétés diversesValeurUnitéNorme du test
Absorption d'eau 0.3 % Sim. to ISO 62
Absorption d'humidité 0.12 % Sim. to ISO 62
Masse volumique 1200 kg/m³ ISO 1183
Bulk density 660 kg/m³ -
Propriétés mécaniques (Grades film)ValeurUnitéNorme du test
ISO Data
Perméabilité à la vapeur d'eau, 23°C/85%r.h. 15 g/(m²*d) ISO 15106-1/-2
Préparation et conditionnement des éprouvettesValeurUnitéNorme du test
ISO Data
Injection, température de la matière fondue 310 °C ISO 294
Injection, température du moule 90 °C ISO 294
Injection, vitesse d'injection 200 mm/s ISO 294
Caractéristiques
Transformation
Moulage par injection, Soufflage
Conditionnement
Granulés
Propriétés spéciales
Transparent, Stérilisable
Certifications
Contact alimentaire, Grade médical, Biocompatibility ISO 10993, USP Class VI approbation
Applications
Médical
Disponibilité régionale
Conditions générales
Copyright Altair Engineering GmbH. Altair Engineering GmbH assumes no liability for the system to be free of errors. The user takes sole responsibility for the use of this data under the exclusion of every liability from Altair Engineering GmbH; this is especially valid for claims of compensation resulting from consequential damages. Altair explicitly points out that any decision about the application of materials must be double checked with the producer of this material. This includes all contents of this system. Copyright laws are applicable for the content of this system.
Created: Source: www.materialdatacenter.com


Material Data Center is provided by M-Base Engineering + Software GmbH. M-Base Engineering + Software GmbH assumes no liability for the system to be free of errors. Any decision about the application of materials must be double checked with the producer of this material.

Additional information about this material, like producer contact address, etc. can be found at www.materialdatacenter.com. For access to this extra information a registration is requested. Free online registration is available.