Material Data Center is a leading international information system for the plastics industry. Material Data Center offers a comprehensive plastics database, calculation tools, CAE interfaces, a literature database and an application database. For more information about Material Data Center visit www.materialdatacenter.com.
This is the free Material Data Center Datasheet of Promyde® B33 BR1 - PA6 - Nurel S.A.
Material Data Center offers the following functions for Promyde® B33 BR1:
unit conversion, PDF datasheet print, comparison with other plastics, snap fit calculation, beam deflection calculation, CAE Interfaces
Check here, which other Promyde datasheets, application examples or technical articles are available in Material Data Center
Use the following short links to get directly to the properties of interest in this datasheet:
Any use of this information falls under the rules of our
disclaimer.
Caractéristiques des transformations/physiques | sec / cond | Unité | Norme du test |
ISO Data |
Indice de fluidité à chaud en volume, MVR |
35 / * |
cm³/10min |
ISO 1133 |
Température |
275 / * |
°C |
- |
Charge |
5 / * |
kg |
- |
Retrait au moulage, parallèle |
1.0 / * |
% |
ISO 294-4, 2577 |
Retrait au moulage, perpendiculaire |
0.9 / * |
% |
ISO 294-4, 2577 |
Propriétés mécaniques | sec / cond | Unité | Norme du test |
ISO Data |
Module en traction |
3400 / 1100 |
MPa |
ISO 527 |
Résistance à la traction |
85 / 40 |
MPa |
ISO 527 |
Déformation au seuil d'écoulement |
4 / 25 |
% |
ISO 527 |
Déformation à la rupture |
50 / >50 |
% |
ISO 527 |
Module de flexion, 23°C |
2900 / 1000 |
MPa |
ISO 178 |
Résistance à la flexion |
110 / 30 |
MPa |
ISO 178 |
Résistance au choc Charpy, +23°C |
N / N |
kJ/m² |
ISO 179/1eU |
Résistance au choc Charpy (entaillé), +23°C |
5.4 / 32 |
kJ/m² |
ISO 179/1eA |
Propriétés thermiques | sec / cond | Unité | Norme du test |
ISO Data |
Température de fusion, 10°C/min |
222 / * |
°C |
ISO 11357-1/-3 |
Température de fléchissement s/chrg, 1.80 MPa |
65 / * |
°C |
ISO 75-1/-2 |
Température de fléchissement s/chrg, 0.45 MPa |
197 / * |
°C |
ISO 75-1/-2 |
Coeffic. de dilatation therm. linéique, parallèle |
70 / * |
E-6/K |
ISO 11359-1/-2 |
Coeffic. de dilatation therm. linéique, perpend. |
100 / * |
E-6/K |
ISO 11359-1/-2 |
Inflammabilité ep. nom. 1.5 mm |
V-2 / * |
class |
IEC 60695-11-10 |
Epaisseur de l'éprouvette |
1.5 / * |
mm |
- |
Propriétés électriques | sec / cond | Unité | Norme du test |
ISO Data |
Indice de résistance au cheminement |
600 / - |
- |
IEC 60112 |
Other Standards[S] |
Permittivité relative, 1MHz |
3.5 / 7 |
- |
IEC 60250 |
Facteur de pertes, 1MHz |
300 / 3000 |
E-4 |
IEC 60250 |
Résistivité transversale |
1E13 / 1E10 |
Ohm*m |
IEC 60093 |
Résistivité superficielle |
* / 1E10 |
Ohm |
IEC 60093 |
S: | These properties are reported by the producer according standards that are different to our defaults. |
Propriétés diverses | sec / cond | Unité | Norme du test |
Absorption d'eau |
9.5 / * |
% |
Sim. to ISO 62 |
Absorption d'humidité |
3 / * |
% |
Sim. to ISO 62 |
Masse volumique |
1130 / - |
kg/m³ |
ISO 1183 |
Propriétés spécifiques à la matière | sec / cond | Unité | Norme du test |
ISO Data |
Indice de viscosité |
203 / * |
cm³/g |
ISO 307, 1157, 1628 |
Recommandations pour la transformation Moulage par injection | Valeur | Unité | Norme du test |
Pré-séchage - température |
<80 |
°C |
- |
Pré-séchage - temps |
4 - 6 |
h |
- |
Température de la matière fondue |
260 - 280 |
°C |
- |
Température du moule |
40 - 80 |
°C |
- |
Caractéristiques
Transformation
Moulage par injection
Conditionnement
Blanc
Additifs
Lubrifiant
Caractéristiques
Nuclée
Disponibilité régionale
Europe
Conditions générales
Copyright Altair Engineering GmbH. Altair Engineering GmbH assumes no liability for the system to be free of errors. The user takes sole responsibility for the use of this data under the exclusion of every liability from Altair Engineering GmbH; this is especially valid for claims of compensation resulting from consequential damages. Altair explicitly points out that any decision about the application of materials must be double checked with the producer of this material. This includes all contents of this system. Copyright laws are applicable for the content of this system.
Created: Source: www.materialdatacenter.com
Material Data Center is provided by M-Base Engineering + Software GmbH. M-Base Engineering + Software GmbH assumes no liability for the system to be free of errors. Any decision about the application of materials must be double checked with the producer of this material.
Additional information about this material, like producer contact address, etc. can be found at www.materialdatacenter.com. For access to this extra information a registration is requested. Free online registration is available.