Material Data Center is a leading international information system for the plastics industry. Material Data Center offers a comprehensive plastics database, calculation tools, CAE interfaces, a literature database and an application database. For more information about Material Data Center visit www.materialdatacenter.com.

This is the free Material Data Center Datasheet of SCHULAMID® 66 GF 35 H - PA66-GF35 - LyondellBasell Industries

Material Data Center offers the following functions for SCHULAMID® 66 GF 35 H:
unit conversion, PDF datasheet print, comparison with other plastics, snap fit calculation, beam deflection calculation, parameters for material models, CAE Interfaces

Check here, which other Schulamid datasheets, application examples or technical articles are available in Material Data Center

Use the following short links to get directly to the properties of interest in this datasheet:
Any use of this information falls under the rules of our disclaimer.
Informations produit
35% glass fibre reinforced heat stabilized PA 66

Propriétés mécaniquessec / condUnitéNorme du test
ISO Data
Module en traction 11000 / 7200 MPa ISO 527
Contrainte à la rupture 190 / 125 MPa ISO 527
Déformation à la rupture 3 / 6 % ISO 527
Résistance au choc Charpy, +23°C 80 / 95 kJ/m² ISO 179/1eU
Résistance au choc Charpy, -30°C 50 / - kJ/m² ISO 179/1eU
Résistance au choc Charpy (entaillé), +23°C 12 / 20 kJ/m² ISO 179/1eA
Résistance au choc Charpy (entaillé), -30°C 10 / - kJ/m² ISO 179/1eA
ASTM Data
Résistance de traction à la rupture 172 / - MPa ASTM D 638
Allongement à la rupture 5 / - % ASTM D 638
Module de flexion 9928 / - MPa ASTM D 790
Résistance à la flexion 228 / - MPa ASTM D 790
Izod choc avec entaille, 1/8 in 64.1 / - J/m ASTM D 256
Propriétés thermiquessec / condUnitéNorme du test
ISO Data
Température de fléchissement s/chrg, 1.80 MPa 246 / * °C ISO 75-1/-2
Température de fléchissement s/chrg, 0.45 MPa 250 / * °C ISO 75-1/-2
Température de ramolliss. Vicat, B 250 / * °C ISO 306
Inflammabilité ep. nom. 1.5 mm HB / * class IEC 60695-11-10
Epaisseur de l'éprouvette 1.5 / * mm -
Inflammabilité pr. épaisseur h HB / * class IEC 60695-11-10
Epaisseur de l'éprouvette 0.8 / * mm -
ASTM Data
DTUL à 66 psi 253 °C ASTM D 648
DTUL à 264 psi 239 °C ASTM D 648
Propriétés électriquessec / condUnitéNorme du test
ISO Data
Résistivité transversale >1E13 / - Ohm*m IEC 62631-3-1
Résistivité superficielle * / >1E15 Ohm IEC 62631-3-2
Propriétés diversessec / condUnitéNorme du test
Masse volumique 1400 / - kg/m³ ISO 1183
Densité 1410 kg/m³ ASTM D 792
Propriétés spécifiques à la matièresec / condUnitéNorme du test
ISO Data
Indice de viscosité 145 / * cm³/g ISO 307, 1157, 1628
Recommandations pour la transformation Moulage par injectionValeurUnitéNorme du test
Pré-séchage - température 80 °C -
Pré-séchage - temps 4 - 6 h -
Température de la matière fondue 290 - 310 °C -
Température du moule 60 - 100 °C -
Fonctions
Viscosité / Vitesse de cisaillement , SCHULAMID® 66 GF 35 H, PA66-GF35, LyondellBasell
Contrainte de cisaillement / Vit. de cisaillement , SCHULAMID® 66 GF 35 H, PA66-GF35, LyondellBasell
Contrainte / Déformation , SCHULAMID® 66 GF 35 H (sec), PA66-GF35, LyondellBasell
Module sécant / Déformation , SCHULAMID® 66 GF 35 H (sec), PA66-GF35, LyondellBasell
Module de traction / Température , SCHULAMID® 66 GF 35 H (sec), PA66-GF35, LyondellBasell
Caractéristiques
Transformation
Moulage par injection
Conditionnement
Grains
Additifs
Agent de démoulage
Propriétés spéciales
Stabilisé à la chaleur
Disponibilité régionale
Autres informations
Moulages par injection
PREPROCESSING; Pretreatment
Predrying: 4-6h / 80°C

PROCESSING ;Processing:

Melttemperature290 - 310°C
Mouldtemperature60 - 100°C
Conditions générales
Copyright Altair Engineering GmbH. Altair Engineering GmbH assumes no liability for the system to be free of errors. The user takes sole responsibility for the use of this data under the exclusion of every liability from Altair Engineering GmbH; this is especially valid for claims of compensation resulting from consequential damages. Altair explicitly points out that any decision about the application of materials must be double checked with the producer of this material. This includes all contents of this system. Copyright laws are applicable for the content of this system.