Material Data Center is a leading international information system for the plastics industry. Material Data Center offers a comprehensive plastics database, calculation tools, CAE interfaces, a literature database and an application database. For more information about Material Data Center visit www.materialdatacenter.com.

This is the free Material Data Center Datasheet of Taroblend 88 G2 - (PC+ABS)-GF10 - Taro Plast S.p.A.

Material Data Center offers the following functions for Taroblend 88 G2:
unit conversion, PDF datasheet print, comparison with other plastics, snap fit calculation, beam deflection calculation, CAE Interfaces

Check here, which other Taroblend datasheets, application examples or technical articles are available in Material Data Center

Use the following short links to get directly to the properties of interest in this datasheet:
Any use of this information falls under the rules of our disclaimer.
Caractéristiques des transformations/physiquesValeurUnitéNorme du test
ISO Data
Indice de fluidité, MFI 12 g/10min ISO 1133
Température 260 °C -
Charge 5 kg -
Propriétés mécaniquesValeurUnitéNorme du test
ISO Data
Module en traction 4000 MPa ISO 527
Contrainte à la rupture 70 MPa ISO 527
Déformation à la rupture 5 % ISO 527
Module de flexion, 23°C 4000 MPa ISO 178
Résistance au choc Charpy, +23°C 25 kJ/m² ISO 179/1eU
Résistance au choc Charpy (entaillé), +23°C 9 kJ/m² ISO 179/1eA
Propriétés thermiquesValeurUnitéNorme du test
ISO Data
Température de fléchissement s/chrg, 1.80 MPa 120 °C ISO 75-1/-2
Température de ramolliss. Vicat, A 140 °C ISO 306
Température de ramolliss. Vicat, B 134 °C ISO 306
Coeffic. de dilatation therm. linéique, parallèle 40 E-6/K ISO 11359-1/-2
ASTM Data
UL 94 inflammabilité HB - UL 94
Épaisseur testée 1.6 mm -
Indice limite d’oxygène 24 % ASTM D 2863
Propriétés électriquesValeurUnitéNorme du test
ISO Data
Résistivité transversale 1E13 Ohm*m IEC 62631-3-1
Rigidité diélectrique 24 kV/mm IEC 60243-1
Indice de résistance au cheminement 150 - IEC 60112
Propriétés diversesValeurUnitéNorme du test
Absorption d'eau 0.29 % Sim. to ISO 62
Masse volumique 1120 kg/m³ ISO 1183
Caractéristiques
Propriétés spéciales
Stabilisé aux intempéries
Caractéristiques
Faible odeur
Applications
Automobile, Électrotechnique et électrique
Disponibilité régionale
Europe
Conditions générales
Copyright Altair Engineering GmbH. Altair Engineering GmbH assumes no liability for the system to be free of errors. The user takes sole responsibility for the use of this data under the exclusion of every liability from Altair Engineering GmbH; this is especially valid for claims of compensation resulting from consequential damages. Altair explicitly points out that any decision about the application of materials must be double checked with the producer of this material. This includes all contents of this system. Copyright laws are applicable for the content of this system.
Created: Source: www.materialdatacenter.com


Material Data Center is provided by M-Base Engineering + Software GmbH. M-Base Engineering + Software GmbH assumes no liability for the system to be free of errors. Any decision about the application of materials must be double checked with the producer of this material.

Additional information about this material, like producer contact address, etc. can be found at www.materialdatacenter.com. For access to this extra information a registration is requested. Free online registration is available.