Complete Set of CAMPUS® Data, ASTM Data, Biopolymer Database, Application Database, Tradename Database, Literature Database, Toolbox.

Material datasheets available free. Online registration at: www.materialdatacenter.com

Material Data Center is a leading international information system for the plastics industry. Material Data Center offers a comprehensive plastics database, calculation tools, CAE interfaces, a literature database and an application database. For more information about Material Data Center visit www.materialdatacenter.com.

This is the free Material Data Center Datasheet of VESTAKEEP® i4 PL - PEEK - Evonik Operations GmbH

Material Data Center offers the following functions for VESTAKEEP® i4 PL:
unit conversion, PDF datasheet print, comparison with other plastics, snap fit calculation, beam deflection calculation, CAE Interfaces

Check here, which other Vestakeep datasheets, application examples or technical articles are available in Material Data Center

Use the following short links to get directly to the properties of interest in this datasheet:
Any use of this information falls under the rules of our disclaimer.
Informations produit
Implantable grade polyether ether ketone plates for permanent implants 
VESTAKEEP® i4 PL are plates based on implantable grade VESTAKEEP® i4 G neat polyether ether ketone resin.
 
Proven Biocompatibility of VESTAKEEP® i-Grades

The extra high purity and extended quality measures make VESTAKEEP® i-Grade materials an excellent choice for permanent implants.

For VESTAKEEP® i4 PL, biocompatibility has been tested according to ISO 10993-1 recommendations for permanent tissue/bone contact and USP Class VI.

VESTAKEEP® i4 PL complies ASTM F2026 “Standard Specification for Polyetheretherketone (PEEK) Polymers for Surgical Implant Applications”.

A summary of biocompatibility test results is available upon request.
 
Biocompatibility tests available for i4 PL

 
Delivery of VESTAKEEP® i-Grades
VESTAKEEP® i4 PL plates have thickness of up to 60 mm, standard width of 500 mm and standard length of 1000 mm.

Custom lengths are also available

FOR FURTHER INFORMATION PLEASE CONTACT US AT EVONIK-HP@EVONIK.COM
OR VISIT OUR PRODUCT AT  WWW.EVONIK.COM/MEDICAL-TECHNOLOGY
Propriétés mécaniquesValeurUnitéNorme du test
ISO Data
Module en traction 4000 MPa ISO 527
Contrainte d'écoulement 109 MPa ISO 527
Déformation au seuil d'écoulement 4.8 % ISO 527
Déformation nominale à la rupture >50 % ISO 527
Propriétés thermiquesValeurUnitéNorme du test
ISO Data
Température de fusion, 10°C/min 340 °C ISO 11357-1/-3
Température de fléchissement s/chrg, 1.80 MPa 155 °C ISO 75-1/-2
Température de fléchissement s/chrg, 0.45 MPa 205 °C ISO 75-1/-2
Propriétés électriquesValeurUnitéNorme du test
ISO Data
Permittivité relative, 1MHz 2.8 - IEC 62631-2-1
Propriétés diversesValeurUnitéNorme du test
Absorption d'eau 0.4 % Sim. to ISO 62
Absorption d'humidité 0.12 % Sim. to ISO 62
Masse volumique 1300 kg/m³ ISO 1183
Caractéristiques
Conditionnement
Produit semi-fini
Certifications
Grade médical, Biocompatibility ISO 10993, USP Class VI approbation
Applications
Médical
Disponibilité régionale
Conditions générales
Copyright Altair Engineering GmbH. Altair Engineering GmbH assumes no liability for the system to be free of errors. The user takes sole responsibility for the use of this data under the exclusion of every liability from Altair Engineering GmbH; this is especially valid for claims of compensation resulting from consequential damages. Altair explicitly points out that any decision about the application of materials must be double checked with the producer of this material. This includes all contents of this system. Copyright laws are applicable for the content of this system.
Created: Source: www.materialdatacenter.com


Material Data Center is provided by M-Base Engineering + Software GmbH. M-Base Engineering + Software GmbH assumes no liability for the system to be free of errors. Any decision about the application of materials must be double checked with the producer of this material.

Additional information about this material, like producer contact address, etc. can be found at www.materialdatacenter.com. For access to this extra information a registration is requested. Free online registration is available.