Complete Set of CAMPUS® Data, ASTM Data, Biopolymer Database, Application Database, Tradename Database, Literature Database, Toolbox.

Material datasheets available free. Online registration at: www.materialdatacenter.com

Material Data Center is a leading international information system for the plastics industry. Material Data Center offers a comprehensive plastics database, calculation tools, CAE interfaces, a literature database and an application database. For more information about Material Data Center visit www.materialdatacenter.com.

This is the free Material Data Center Datasheet of Haiplen H50 X2 - PP - Taro Plast S.p.A.

Material Data Center offers the following functions for Haiplen H50 X2:
unit conversion, PDF datasheet print, comparison with other plastics, snap fit calculation, beam deflection calculation, CAE Interfaces

Check here, which other Haiplen datasheets, application examples or technical articles are available in Material Data Center

Use the following short links to get directly to the properties of interest in this datasheet:
Any use of this information falls under the rules of our disclaimer.
Caractéristiques des transformations/physiquesValeurUnitéNorme du test
ISO Data
Indice de fluidité, MFI 10 g/10min ISO 1133
Température 230 °C -
Charge 2.16 kg -
Propriétés mécaniquesValeurUnitéNorme du test
ISO Data
Module en traction 1700 MPa ISO 527
Contrainte d'écoulement 25 MPa ISO 527
Déformation à la rupture >50 % ISO 527
Module de flexion, 23°C 1500 MPa ISO 178
Résistance au choc Charpy (entaillé), +23°C 3.2 kJ/m² ISO 179/1eA
ASTM Data
Izod choc avec entaille, 1/8 in 35 J/m ASTM D 256
Izod choc avec entaille, bas température 25 J/m ASTM D 256
Température -23 °C -
Propriétés thermiquesValeurUnitéNorme du test
ISO Data
Température de fusion, 10°C/min 163 °C ISO 11357-1/-3
Température de fléchissement s/chrg, 1.80 MPa 65 °C ISO 75-1/-2
Température de fléchissement s/chrg, 0.45 MPa 120 °C ISO 75-1/-2
Température de ramolliss. Vicat, A 155 °C ISO 306
Température de ramolliss. Vicat, B 90 °C ISO 306
Inflammabilité ep. nom. 1.5 mm V-2 class IEC 60695-11-10
ASTM Data
UL 94 inflammabilité V-2 - UL 94
Épaisseur testée 3.2 mm -
Indice limite d’oxygène 26 % ASTM D 2863
Propriétés diversesValeurUnitéNorme du test
Absorption d'eau 0.03 % Sim. to ISO 62
Masse volumique 960 kg/m³ ISO 1183
Caractéristiques
Propriétés spéciales
Ignifugé, Stabilisé aux intempéries, Stabilisé à la chaleur
Caractéristiques
Marquage au laser, Faible odeur, Homopolymère
Applications
Automobile, Électrotechnique et électrique
Disponibilité régionale
Europe
Conditions générales
Copyright Altair Engineering GmbH. Altair Engineering GmbH assumes no liability for the system to be free of errors. The user takes sole responsibility for the use of this data under the exclusion of every liability from Altair Engineering GmbH; this is especially valid for claims of compensation resulting from consequential damages. Altair explicitly points out that any decision about the application of materials must be double checked with the producer of this material. This includes all contents of this system. Copyright laws are applicable for the content of this system.
Created: Source: www.materialdatacenter.com


Material Data Center is provided by M-Base Engineering + Software GmbH. M-Base Engineering + Software GmbH assumes no liability for the system to be free of errors. Any decision about the application of materials must be double checked with the producer of this material.

Additional information about this material, like producer contact address, etc. can be found at www.materialdatacenter.com. For access to this extra information a registration is requested. Free online registration is available.