Complete Set of CAMPUS® Data, ASTM Data, Biopolymer Database, Application Database, Tradename Database, Literature Database, Toolbox.

Material datasheets available free. Online registration at: www.materialdatacenter.com

Material Data Center is a leading international information system for the plastics industry. Material Data Center offers a comprehensive plastics database, calculation tools, CAE interfaces, a literature database and an application database. For more information about Material Data Center visit www.materialdatacenter.com.

This is the free Material Data Center Datasheet of RTP 6091-85A PA12 BLACK - TPE - RTP Company

Material Data Center offers the following functions for RTP 6091-85A PA12 BLACK:
unit conversion, PDF datasheet print, comparison with other plastics

Check here, which other RTP datasheets, application examples or technical articles are available in Material Data Center

Use the following short links to get directly to the properties of interest in this datasheet:
Any use of this information falls under the rules of our disclaimer.
Propriétés mécaniquesValeurUnitéNorme du test
ASTM Data
Module à 100% allongement 4.83 MPa ASTM D 412
Dureté D Shore 85 - ASTM D 2240
Résistance au déchirement 29.8 kN/m ASTM D 624
Compression rémanente, 22 hr @ 158 °F 37 % ASTM D 395
Résistance de traction à la rupture 8.14 MPa ASTM D 412
Allongement à la rupture 400 % ASTM D 412
Propriétés diversesValeurUnitéNorme du test
Densité 970 kg/m³ ASTM D 792
Moisture Content 0.08 % -
Recommandations pour la transformation Moulage par injectionValeurUnitéNorme du test
Pré-séchage - température 82.2 °C -
Pré-séchage - temps 4 h -
Température de la matière fondue 263 - 282 °C -
Température du moule 35 - 71.1 °C -
Caractéristiques
Transformation
Moulage par injection
Conditionnement
Noir
Disponibilité régionale
Amérique du nord, Europe, Asia Pacific
Conditions générales
Copyright Altair Engineering GmbH. Altair Engineering GmbH assumes no liability for the system to be free of errors. The user takes sole responsibility for the use of this data under the exclusion of every liability from Altair Engineering GmbH; this is especially valid for claims of compensation resulting from consequential damages. Altair explicitly points out that any decision about the application of materials must be double checked with the producer of this material. This includes all contents of this system. Copyright laws are applicable for the content of this system.