Complete Set of CAMPUS® Data, ASTM Data, Biopolymer Database, Application Database, Tradename Database, Literature Database, Toolbox.

Material datasheets available free. Online registration at: www.materialdatacenter.com

Material Data Center is a leading international information system for the plastics industry. Material Data Center offers a comprehensive plastics database, calculation tools, CAE interfaces, a literature database and an application database. For more information about Material Data Center visit www.materialdatacenter.com.

This is the free Material Data Center Datasheet of VECTRA® E150i - LCP-GF50 - Celanese

Material Data Center offers the following functions for VECTRA® E150i:
unit conversion, PDF datasheet print, comparison with other plastics, snap fit calculation, beam deflection calculation, CAE Interfaces

Check here, which other Vectra datasheets, application examples or technical articles are available in Material Data Center

Use the following short links to get directly to the properties of interest in this datasheet:
Any use of this information falls under the rules of our disclaimer.
Informations produit
Easy flowing grade with very good heat resistance, and mechanical properties. May reduce warpage in some parts compared to E130i. 50% glass reinforced. Chemical abbreviation according to ISO 1043-1 : LCP Inherently flame retardant FDA compliant UL-Listing V-0 in natural and black at 0.43mm thickness per UL 94 flame testing. Relative-Temperature-Index (RTI) according to UL 746B: electricals 240°C, mechanicals 240°C at 0.75mm. UL = Underwriters Laboratories (USA)

Flammability @1.6mm nom. thickn.V-0-
Flammability at thickness h (0.43 mm)V-0UL recognition (h)
Caractéristiques des transformations/physiquesValeurUnitéNorme du test
ISO Data
Retrait au moulage, parallèle 0.2 % ISO 294-4, 2577
Retrait au moulage, perpendiculaire 0.5 % ISO 294-4, 2577
Propriétés mécaniquesValeurUnitéNorme du test
ISO Data
Module en traction 20000 MPa ISO 527
Contrainte à la rupture 130 MPa ISO 527
Déformation à la rupture 1 % ISO 527
Résistance au choc Charpy, +23°C 19 kJ/m² ISO 179/1eU
Résistance au choc Charpy (entaillé), +23°C 10 kJ/m² ISO 179/1eA
Propriétés thermiquesValeurUnitéNorme du test
ISO Data
Température de fusion, 10°C/min 335 °C ISO 11357-1/-3
Température de fléchissement s/chrg, 1.80 MPa 260 °C ISO 75-1/-2
Température de fléchissement s/chrg, 8.00 MPa 225 °C ISO 75-1/-2
Température de ramolliss. Vicat, B 200 °C ISO 306
Coeffic. de dilatation therm. linéique, parallèle 6 E-6/K ISO 11359-1/-2
Coeffic. de dilatation therm. linéique, perpend. 17 E-6/K ISO 11359-1/-2
Inflammabilité ep. nom. 1.5 mm V-0 class IEC 60695-11-10
Epaisseur de l'éprouvette 1.5 mm -
Inflammabilité pr. épaisseur h V-0 class IEC 60695-11-10
Epaisseur de l'éprouvette 0.4 mm -
Yellow Card disponible oui - -
Propriétés électriquesValeurUnitéNorme du test
ISO Data
Permittivité relative, 1MHz 4.7 - IEC 62631-2-1
Facteur de pertes, 1MHz 280 E-4 IEC 62631-2-1
Résistivité transversale 1E13 Ohm*m IEC 62631-3-1
Résistivité superficielle 1E14 Ohm IEC 62631-3-2
Rigidité diélectrique 28 kV/mm IEC 60243-1
Propriétés diversesValeurUnitéNorme du test
Absorption d'humidité 0.006 % Sim. to ISO 62
Masse volumique 1810 kg/m³ ISO 1183
Fonctions
Contrainte / Déformation , VECTRA® E150i, LCP-GF50, Celanese
Module sécant / Déformation , VECTRA® E150i, LCP-GF50, Celanese
Caractéristiques
Conditionnement
Noir, Couleurs naturelles
Propriétés spéciales
Ignifugé, Stabilisé à la chaleur
Caractéristiques
Bas gauchissement
Certifications
Contact alimentaire, FDA 21 CFR approbation
Disponibilité régionale
Amérique du nord, Europe, Asia Pacific
Conditions générales
Copyright Altair Engineering GmbH. Altair Engineering GmbH assumes no liability for the system to be free of errors. The user takes sole responsibility for the use of this data under the exclusion of every liability from Altair Engineering GmbH; this is especially valid for claims of compensation resulting from consequential damages. Altair explicitly points out that any decision about the application of materials must be double checked with the producer of this material. This includes all contents of this system. Copyright laws are applicable for the content of this system.
Created: Source: www.materialdatacenter.com


Material Data Center is provided by M-Base Engineering + Software GmbH. M-Base Engineering + Software GmbH assumes no liability for the system to be free of errors. Any decision about the application of materials must be double checked with the producer of this material.

Additional information about this material, like producer contact address, etc. can be found at www.materialdatacenter.com. For access to this extra information a registration is requested. Free online registration is available.