Complete Set of CAMPUS® Data, ASTM Data, Biopolymer Database, Application Database, Tradename Database, Literature Database, Toolbox.

Material datasheets available free. Online registration at: www.materialdatacenter.com

Material Data Center is a leading international information system for the plastics industry. Material Data Center offers a comprehensive plastics database, calculation tools, CAE interfaces, a literature database and an application database. For more information about Material Data Center visit www.materialdatacenter.com.

This is the free Material Data Center Datasheet of Makrolon® FR6019 CTI - PC - Covestro Deutschland AG

Material Data Center offers the following functions for Makrolon® FR6019 CTI:
unit conversion, PDF datasheet print, comparison with other plastics, snap fit calculation, beam deflection calculation, CAE Interfaces

Check here, which other Makrolon datasheets, application examples or technical articles are available in Material Data Center

Use the following short links to get directly to the properties of interest in this datasheet:
Any use of this information falls under the rules of our disclaimer.
Caratteristiche FisicheValoreUnitáNorma del test
ISO Data
Indice di fusione di volume, MVR 13 cm³/10min ISO 1133
Temperatura 300 °C -
Carico 1.2 kg -
Ritiro di stampaggio, parallelo 0.6 % ISO 294-4, 2577
Ritiro di stampaggio, perpendicolare 0.6 % ISO 294-4, 2577
Proprietà MeccanicheValoreUnitáNorma del test
ISO Data
Modulo a trazione 2470 MPa ISO 527
Carico unitario a trazione 66 MPa ISO 527
Deformazione a snervamento 6 % ISO 527
Deformazione nominale a rottura >50 % ISO 527
Carico unitario a rottura 66 MPa ISO 527
Deformazione a rottura 119 % ISO 527
Modulo a flessione, 23°C 2450 MPa ISO 178
Resistenza alla flessione 99 MPa ISO 178
Resistenza all'urto Charpy, +23°C N kJ/m² ISO 179/1eU
Resist. urto Charpy con intaglio, +23°C 11 kJ/m² ISO 179/1eA
Resistenza all'urto Izod con intaglio, +23°C 9 kJ/m² ISO 180/1A
Perforazione-forza massima, +23°C 5200 N ISO 6603-2
Energia di perforazione, +23°C 58 J ISO 6603-2
Ball indentation hardness 128 MPa ISO 2039-1
Proprietà TermicheValoreUnitáNorma del test
ISO Data
Temp.di inflessione sotto carico, 1.80 MPa 112 °C ISO 75-1/-2
Temp.di inflessione sotto carico, 0.45 MPa 125 °C ISO 75-1/-2
Temp.di rammollimento Vicat, B 130 °C ISO 306
Coeff.di dilatazione termica lin., parallelo 70 E-6/K ISO 11359-1/-2
Coeff.di dilatazione termica lin. , perpend. 71 E-6/K ISO 11359-1/-2
Reaz. al fuoco spess.nom. 1.5mm V-0 class IEC 60695-11-10
Spessore provato 1.5 mm -
Yellow Card disponibile - -
Glow Wire Flammability Index (GWFI) 960 °C IEC 60695-2-12
GWFI - thickness tested (1) 1.5 mm -
Glow Wire Flammability Index (GWFI) 960 °C IEC 60695-2-12
GWFI - thickness tested (2) 3 mm -
Glow Wire Ignition Temperature (GWIT) 825 °C IEC 60695-2-13
GWIT - thickness tested (1) 1.5 mm -
Glow Wire Ignition Temperature (GWIT) 825 °C IEC 60695-2-13
GWIT - thickness tested (2) 3 mm -
Proprietà ElettricheValoreUnitáNorma del test
ISO Data
Resistività volumica 4E17 Ohm*m IEC 62631-3-1
Resistività superficiale 5E16 Ohm IEC 62631-3-2
Rigidità dielettrica 31 kV/mm IEC 60243-1
Res. Alle correnti striscianti superficiali 600 - IEC 60112
Altre ProprietàValoreUnitáNorma del test
Massa volumica 1200 kg/m³ ISO 1183
Raccomandazione de Processabilità Stampaggio ad IniezioneValoreUnitáNorma del test
Pre-essiccamento - Temperatura 120 °C -
Pre-essiccamento - Tempo 4 h -
Temperatura di fusione 280 - 310 °C -
Caratteristiche
Processabilità e Forma di Forni
Stampaggio ad Iniezione
Caratteristiche speciali
Ritardante di fiamma
Applicazioni
Automotive, Elettrotecnica ed electrici, Imballaggio
Disponibilità geografica
Nord America, Europa, Asia Oceano Pacifico, Near East/Africa
Disclaimer
Copyright Altair Engineering GmbH. Altair Engineering GmbH assumes no liability for the system to be free of errors. The user takes sole responsibility for the use of this data under the exclusion of every liability from Altair Engineering GmbH; this is especially valid for claims of compensation resulting from consequential damages. Altair explicitly points out that any decision about the application of materials must be double checked with the producer of this material. This includes all contents of this system. Copyright laws are applicable for the content of this system.
Created: Source: www.materialdatacenter.com


Material Data Center is provided by M-Base Engineering + Software GmbH. M-Base Engineering + Software GmbH assumes no liability for the system to be free of errors. Any decision about the application of materials must be double checked with the producer of this material.

Additional information about this material, like producer contact address, etc. can be found at www.materialdatacenter.com. For access to this extra information a registration is requested. Free online registration is available.