Complete Set of CAMPUS® Data, ASTM Data, Biopolymer Database, Application Database, Tradename Database, Literature Database, Toolbox.

Material datasheets available free. Online registration at: www.materialdatacenter.com

Material Data Center is a leading international information system for the plastics industry. Material Data Center offers a comprehensive plastics database, calculation tools, CAE interfaces, a literature database and an application database. For more information about Material Data Center visit www.materialdatacenter.com.

This is the free Material Data Center Datasheet of RTP 4485 - PA*-CF30 - RTP Company

Material Data Center offers the following functions for RTP 4485:
unit conversion, PDF datasheet print, comparison with other plastics

Check here, which other RTP datasheets, application examples or technical articles are available in Material Data Center

Use the following short links to get directly to the properties of interest in this datasheet:
Any use of this information falls under the rules of our disclaimer.
Caratteristiche FisicheValoreUnitáNorma del test
ASTM Data
Ritiro di stampaggio, parallelo 0.00075 mm/mm ASTM D 955
Proprietà MeccanicheValoreUnitáNorma del test
ASTM Data
Modulo a trazione 24130 MPa ASTM D 638
Resistenza alla trazione 248 MPa ASTM D 638
Modulo a flessione 20680 MPa ASTM D 790
Resistenza alla flessione 359 MPa ASTM D 790
Durezza Rockwell R 125 - ASTM D 785
Resistenza all'urto Izod con intaglio, 1/8 in 64.1 J/m ASTM D 256
Proprietà TermicheValoreUnitáNorma del test
ASTM Data
DTUL a 264 psi 260 °C ASTM D 648
Altre ProprietàValoreUnitáNorma del test
Assorbimento d’acqua, 24hr 0.4 % ASTM D 570
Densità 1300 kg/m³ ASTM D 792
Moisture Content 0.1 % -
Raccomandazione de Processabilità Stampaggio ad IniezioneValoreUnitáNorma del test
Pre-essiccamento - Temperatura 79.4 °C -
Pre-essiccamento - Tempo 4 h -
Temperatura di fusione 310 - 343 °C -
Temperatura dello stampo 135 - 163 °C -
Pressione di Iniezione 68.9 - 103 MPa -
Caratteristiche
Processabilità e Forma di Forni
Stampaggio ad Iniezione
Caratteristiche speciali
Stabilizzato o stabile al calore
Disponibilità geografica
Nord America, Europa, Asia Oceano Pacifico
Disclaimer
Copyright Altair Engineering GmbH. Altair Engineering GmbH assumes no liability for the system to be free of errors. The user takes sole responsibility for the use of this data under the exclusion of every liability from Altair Engineering GmbH; this is especially valid for claims of compensation resulting from consequential damages. Altair explicitly points out that any decision about the application of materials must be double checked with the producer of this material. This includes all contents of this system. Copyright laws are applicable for the content of this system.
Created: Source: www.materialdatacenter.com


Material Data Center is provided by M-Base Engineering + Software GmbH. M-Base Engineering + Software GmbH assumes no liability for the system to be free of errors. Any decision about the application of materials must be double checked with the producer of this material.

Additional information about this material, like producer contact address, etc. can be found at www.materialdatacenter.com. For access to this extra information a registration is requested. Free online registration is available.