Complete Set of CAMPUS® Data, ASTM Data, Biopolymer Database, Application Database, Tradename Database, Literature Database, Toolbox.

Material datasheets available free. Online registration at: www.materialdatacenter.com

Material Data Center is a leading international information system for the plastics industry. Material Data Center offers a comprehensive plastics database, calculation tools, CAE interfaces, a literature database and an application database. For more information about Material Data Center visit www.materialdatacenter.com.

This is the free Material Data Center Datasheet of VESTAMID® Care ML-GB30 - PA12-GB30 - Evonik Operations GmbH

Material Data Center offers the following functions for VESTAMID® Care ML-GB30:
unit conversion, PDF datasheet print, comparison with other plastics, snap fit calculation, beam deflection calculation, cooling time calculation, parameters for material models, CAE Interfaces

Check here, which other Vestamid datasheets, application examples or technical articles are available in Material Data Center

Use the following short links to get directly to the properties of interest in this datasheet:
Any use of this information falls under the rules of our disclaimer.
Testo del prodotto

Microglass bead-filled (30%) PA12 resin for the injection moulding of rigid, low-warpage and dimensionally accurate mouldings

 

Biocompatibility of VESTAMID® Care ME

Biocompatiblity was tested following ISO10993-1 recommendations for a surface medical device with up to 30 days body contact.
 
The material fulfills the requirements of USP<88> class VI.
 
Tests were performed by independent, certified laboratories.

Biocompatibility tests for VESTAMID® Care:
Standard Description
ASTM F756-08 Hemocompatibility
ISO 10993-5 Cytotoxicity
ISO 10993-10 Sensitization: Maximization test according to Magnusson and Kligman
ISO 10993-10 Irritation: Intracutaneous Reactivity
ISO 10993-11 Acute Systemic Toxicity
USP Class VI Acute Systemic Toxicity Intracutaneous Reactivity Muscle Implantation


Processing of VESTAMID® Care
For information about processing of VESTAMID®, please follow the general commendations about “Processing of VESTAMID® compounds”. 



The values presented are typical or average values, they do not constitute a specification.

FOR FURTHER INFORMATION PLEASE CONTACT US AT EVONIK-HP@EVONIK.COM
OR VISIT OUR PRODUCT AT  WWW.EVONIK.COM/MEDICAL-TECHNOLOGY

 

Caratteristiche Fisichesecco/condUnitáNorma del test
ISO Data
Indice di fusione di volume, MVR 100 / * cm³/10min ISO 1133
Temperatura 275 / * °C -
Carico 5 / * kg -
Ritiro di stampaggio, parallelo 0.6 / * % ISO 294-4, 2577
Ritiro di stampaggio, perpendicolare 0.7 / * % ISO 294-4, 2577
Densità del fuso 1090 kg/m³ -
Conduttività termica del fuso 0.28 W/(m K) -
Capacità termica specifica del fuso 2400 J/(kg K) -
Temperatura di estrazione 180 °C -
Proprietà Meccanichesecco/condUnitáNorma del test
ISO Data
Modulo a trazione 2100 / 1800 MPa ISO 527
Carico unitario a trazione 47 / 37 MPa ISO 527
Deformazione a snervamento 5 / 5 % ISO 527
Deformazione nominale a rottura 20 / >50 % ISO 527
Modulo di scorrimento a trazione, 1h * / 1600 MPa ISO 899-1
Modulo di scorrimento a trazione, 1000h * / 1100 MPa ISO 899-1
Resistenza all'urto Charpy, +23°C 160 / N kJ/m² ISO 179/1eU
Type of failure C / - - -
Resistenza all'urto Charpy, -30°C 160 / N kJ/m² ISO 179/1eU
Type of failure C / - - -
Resistenzia all'urto Charpy con intaglio, +23°C 4.4 / 6 kJ/m² ISO 179/1eA
Type of failure C / C - -
Resistenzia all'urto Charpy con intaglio, -30°C 6 / 6 kJ/m² ISO 179/1eA
Type of failure C / C - -
Proprietà Termichesecco/condUnitáNorma del test
ISO Data
Temperatura di fusione, 10°C/min 178 / * °C ISO 11357-1/-3
Temp.di inflessione sotto carico, 1.80 MPa 55 / * °C ISO 75-1/-2
Temp.di inflessione sotto carico, 0.45 MPa 150 / * °C ISO 75-1/-2
Temp.di rammollimento Vicat, B 155 / * °C ISO 306
Coeff.di dilatazione termica lin., parallelo 130 / * E-6/K ISO 11359-1/-2
Coeff.di dilatazione termica lin., perpend. 130 / * E-6/K ISO 11359-1/-2
Reaz. al fuoco spess.nom. 1.5mm HB / * class IEC 60695-11-10
Spessore provato 1.6 / * mm -
Proprietà Elettrichesecco/condUnitáNorma del test
ISO Data
Costante dielettrica relativa, 100Hz 4.1 / 5 - IEC 62631-2-1
Costante dielettrica relativa, 1MHz 3.5 / 4 - IEC 62631-2-1
Fattore di dissipazione, 100Hz 310 / 600 E-4 IEC 62631-2-1
Fattore di dissipazione, 1MHz 230 / 370 E-4 IEC 62631-2-1
Resistività volumica >1E13 / 2E12 Ohm*m IEC 62631-3-1
Resistività superficiale * / 1E15 Ohm IEC 62631-3-2
Rigidità dielettrica - / 36 kV/mm IEC 60243-1
Res. Alle correnti striscianti superficiali 600 / 600 - IEC 60112
Altre Proprietàsecco/condUnitáNorma del test
Assorbimento d'acqua 1.1 / * % Sim. alla ISO 62
Assorbimento d'umidità 0.5 / * % Sim. alla ISO 62
Massa volumica 1250 / 1260 kg/m³ ISO 1183
Preparazione ProvetteValoreUnitáNorma del test
ISO Data
Stamp. ad Iniezione, temp. di fusione 250 °C ISO 294
Stamp. ad Iniezione, temperatura dello stampo 80 °C ISO 294
Stamp. ad Iniezione, velocità media d'iniezione 200 mm/s ISO 294
Stamp. ad Iniezione, pressione di chiusura 70 MPa ISO 294
Funzioni
Viscosità-Velocità di taglio , VESTAMID® Care ML-GB30, PA12-GB30, Evonik
Sforzo di taglio-Velocità di taglio , VESTAMID® Care ML-GB30, PA12-GB30, Evonik
Modulo dinamico a taglio-temperatura , VESTAMID® Care ML-GB30 (Secco), PA12-GB30, Evonik
Sforzi-deformazione , VESTAMID® Care ML-GB30 (Secco), PA12-GB30, Evonik
Modulo secante-deformazione , VESTAMID® Care ML-GB30 (Secco), PA12-GB30, Evonik
Sforzi-deformazioni (isocrona) 23°C, VESTAMID® Care ML-GB30 (cond.), PA12-GB30, Evonik
Modulo di scorrimento-tempo 23°C, VESTAMID® Care ML-GB30 (cond.), PA12-GB30, Evonik
Curva di scorrimento 23°C, VESTAMID® Care ML-GB30 (cond.), PA12-GB30, Evonik
Caratteristiche
Processabilità e Forma di Forni
Stampaggio ad Iniezione
Forma fisica disponibile
Pellet
Caratteristiche
Bassa deformazione
Certifications
Grado medico, Biocompatibility ISO 10993, Approvazione della USP class VI
Applicazioni
Medicale
Disponibilità geografica
Nord America, Europa, Asia Oceano Pacifico, South and Central America, Near East/Africa
Disclaimer
Copyright Altair Engineering GmbH. Altair Engineering GmbH assumes no liability for the system to be free of errors. The user takes sole responsibility for the use of this data under the exclusion of every liability from Altair Engineering GmbH; this is especially valid for claims of compensation resulting from consequential damages. Altair explicitly points out that any decision about the application of materials must be double checked with the producer of this material. This includes all contents of this system. Copyright laws are applicable for the content of this system.
Created: Source: www.materialdatacenter.com


Material Data Center is provided by M-Base Engineering + Software GmbH. M-Base Engineering + Software GmbH assumes no liability for the system to be free of errors. Any decision about the application of materials must be double checked with the producer of this material.

Additional information about this material, like producer contact address, etc. can be found at www.materialdatacenter.com. For access to this extra information a registration is requested. Free online registration is available.