Complete Set of CAMPUS® Data, ASTM Data, Biopolymer Database, Application Database, Tradename Database, Literature Database, Toolbox.

Material datasheets available free. Online registration at: www.materialdatacenter.com

Material Data Center is a leading international information system for the plastics industry. Material Data Center offers a comprehensive plastics database, calculation tools, CAE interfaces, a literature database and an application database. For more information about Material Data Center visit www.materialdatacenter.com.

This is the free Material Data Center Datasheet of MAGNUM™ 1250 BG - ABS - Trinseo

Material Data Center offers the following functions for MAGNUM™ 1250 BG:
unit conversion, PDF datasheet print, comparison with other plastics

Check here, which other Magnum datasheets, application examples or technical articles are available in Material Data Center

Use the following short links to get directly to the properties of interest in this datasheet:
Any use of this information falls under the rules of our disclaimer.
Caratteristiche FisicheValoreUnitáNorma del test
ISO Data
Indice di Fluiditá, MFI 1.7 g/10min ISO 1133
Temperatura 220 °C -
Carico 10 kg -
ASTM Data
Indice di fluidità a caldo, MFI 1.7 g/10min ASTM D 1238
Temperatura 230 °C -
Carico 3.8 kg -
Proprietà MeccanicheValoreUnitáNorma del test
ISO Data
Carico unitario a trazione 33.7 MPa ISO 527
Modulo a flessione, 23°C 1810 MPa ISO 178
Resistenza all'urto Izod con intaglio, +23°C 26 kJ/m² ISO 180/1A
Resistenza all'urto Izod con intaglio 17 kJ/m² ISO 180/1A
Temperatura -30 °C -
ASTM Data
Resistenza alla trazione di snervamento 33.6 MPa ASTM D 638
Allungamento a rottura 60 % ASTM D 638
Modulo a flessione 2013 MPa ASTM D 790
Resistenza all'urto Izod con intaglio, 1/8 in 358 J/m ASTM D 256
Resistenza all'urto Izod con intaglio, basso temperatura 187 J/m ASTM D 256
Temperatura -28.9 °C -
Proprietà TermicheValoreUnitáNorma del test
ISO Data
Temp.di inflessione sotto carico, 1.80 MPa 85 °C ISO 75-1/-2
Temp.di inflessione sotto carico, 0.45 MPa 101 °C ISO 75-1/-2
ASTM Data
DTUL a 66 psi 103 °C ASTM D 648
DTUL a 264 psi 86.7 °C ASTM D 648
Altre ProprietàValoreUnitáNorma del test
Densità 1050 kg/m³ ASTM D 792
Caratteristiche
Processabilità e Forma di Forni
Soffiaggio
Caratteristiche speciali
Alto urto o modificato all'urto, Stabilizzato o stabile al calore
Disponibilità geografica
Nord America
Disclaimer
Copyright Altair Engineering GmbH. Altair Engineering GmbH assumes no liability for the system to be free of errors. The user takes sole responsibility for the use of this data under the exclusion of every liability from Altair Engineering GmbH; this is especially valid for claims of compensation resulting from consequential damages. Altair explicitly points out that any decision about the application of materials must be double checked with the producer of this material. This includes all contents of this system. Copyright laws are applicable for the content of this system.
Created: Source: www.materialdatacenter.com


Material Data Center is provided by M-Base Engineering + Software GmbH. M-Base Engineering + Software GmbH assumes no liability for the system to be free of errors. Any decision about the application of materials must be double checked with the producer of this material.

Additional information about this material, like producer contact address, etc. can be found at www.materialdatacenter.com. For access to this extra information a registration is requested. Free online registration is available.