Complete Set of CAMPUS® Data, ASTM Data, Biopolymer Database, Application Database, Tradename Database, Literature Database, Toolbox.

Material datasheets available free. Online registration at: www.materialdatacenter.com

Material Data Center is a leading international information system for the plastics industry. Material Data Center offers a comprehensive plastics database, calculation tools, CAE interfaces, a literature database and an application database. For more information about Material Data Center visit www.materialdatacenter.com.

This is the free Material Data Center Datasheet of Makrolon® 3638 - PC - Covestro Deutschland AG

Material Data Center offers the following functions for Makrolon® 3638:
unit conversion, PDF datasheet print, comparison with other plastics, snap fit calculation, beam deflection calculation, CAE Interfaces

Check here, which other Makrolon datasheets, application examples or technical articles are available in Material Data Center

Use the following short links to get directly to the properties of interest in this datasheet:
Any use of this information falls under the rules of our disclaimer.
Testo del prodotto
  • MVR (300 °C/1.2 kg) 2.0 cm³/10 min
  • high viscosity
  • food contact quality
  • biocompatible according to many ISO 10993-1 test requirements
  • pharmaceutical applications
  • medical devices
Caratteristiche FisicheValoreUnitáNorma del test
ISO Data
Indice di fusione di volume, MVR 2 cm³/10min ISO 1133
Temperatura 300 °C -
Carico 1.2 kg -
Indice di Fluiditá, MFI 2.5 g/10min ISO 1133
Temperatura 300 °C -
Carico 1.2 kg -
Ritiro di stampaggio, parallelo 0.8 % ISO 294-4, 2577
Ritiro di stampaggio, perpendicolare 0.8 % ISO 294-4, 2577
Proprietà MeccanicheValoreUnitáNorma del test
ISO Data
Modulo a trazione 2300 MPa ISO 527
Carico unitario a trazione 64 MPa ISO 527
Deformazione a snervamento 6.6 % ISO 527
Deformazione nominale a rottura >50 % ISO 527
Modulo a flessione, 23°C 2300 MPa ISO 178
Resistenza alla flessione 94 MPa ISO 178
Resistenza all'urto Charpy, +23°C N kJ/m² ISO 179/1eU
Resist. urto Charpy con intaglio, +23°C, 3mm 75 kJ/m² ISO 179/1eA
Type of failure P - -
Resist. urto Charpy con intaglio, -30°C, 3mm 20 kJ/m² ISO 179/1eA
Type of failure C(P) - -
Resistenza all'urto Izod con intaglio, +23°C 65 kJ/m² ISO 180/1A
Resistenza all'urto Izod con intaglio 55 kJ/m² ISO 180/1A
Temperatura -30 °C -
Perforazione-forza massima, +23°C 5500 N ISO 6603-2
Perforazione-forza massima, -30°C 6400 N ISO 6603-2
Energia di perforazione, +23°C 55 J ISO 6603-2
Energia di perforazione, -30°C 60 J ISO 6603-2
Ball indentation hardness 108 MPa ISO 2039-1
Proprietà TermicheValoreUnitáNorma del test
ISO Data
Temperatura di transizione vetrosa, 10°C/min 152 °C ISO 11357-1/-2
Temp.di inflessione sotto carico, 1.80 MPa 132 °C ISO 75-1/-2
Temp.di inflessione sotto carico, 0.45 MPa 145 °C ISO 75-1/-2
Temp.di rammollimento Vicat, B 150 °C ISO 306
Coeff.di dilatazione termica lin., parallelo 70 E-6/K ISO 11359-1/-2
Coeff.di dilatazione termica lin., perpend. 70 E-6/K ISO 11359-1/-2
Indice di ossigeno 26 % ISO 4589-1/-2
Altre ProprietàValoreUnitáNorma del test
Assorbimento d'acqua 0.3 % Sim. alla ISO 62
Assorbimento d'umidità 0.12 % Sim. alla ISO 62
Massa volumica 1200 kg/m³ ISO 1183
Bulk density 660 kg/m³ -
Proprietà Meccaniche (Film)ValoreUnitáNorma del test
ISO Data
WVTR, 23°C/85%r.h. 15 g/(m²*d) ISO 15106-1/-2
Preparazione ProvetteValoreUnitáNorma del test
ISO Data
Stamp. ad Iniezione, temp. di fusione 310 °C ISO 294
Stamp. ad Iniezione, temperatura dello stampo 90 °C ISO 294
Stamp. ad Iniezione, velocità media d'iniezione 200 mm/s ISO 294
Caratteristiche
Processabilità e Forma di Forni
Stampaggio ad Iniezione, Soffiaggio
Forma fisica disponibile
Pellet
Caratteristiche speciali
Trasparente, Sterilizzabile
Certifications
Contatto con gli alimenti, Grado medico, Biocompatibility ISO 10993, Approvazione della USP class VI
Applicazioni
Medicale
Disponibilità geografica
Disclaimer
Copyright Altair Engineering GmbH. Altair Engineering GmbH assumes no liability for the system to be free of errors. The user takes sole responsibility for the use of this data under the exclusion of every liability from Altair Engineering GmbH; this is especially valid for claims of compensation resulting from consequential damages. Altair explicitly points out that any decision about the application of materials must be double checked with the producer of this material. This includes all contents of this system. Copyright laws are applicable for the content of this system.
Created: Source: www.materialdatacenter.com


Material Data Center is provided by M-Base Engineering + Software GmbH. M-Base Engineering + Software GmbH assumes no liability for the system to be free of errors. Any decision about the application of materials must be double checked with the producer of this material.

Additional information about this material, like producer contact address, etc. can be found at www.materialdatacenter.com. For access to this extra information a registration is requested. Free online registration is available.