Complete Set of CAMPUS® Data, ASTM Data, Biopolymer Database, Application Database, Tradename Database, Literature Database, Toolbox.

Material datasheets available free. Online registration at: www.materialdatacenter.com

Material Data Center is a leading international information system for the plastics industry. Material Data Center offers a comprehensive plastics database, calculation tools, CAE interfaces, a literature database and an application database. For more information about Material Data Center visit www.materialdatacenter.com.

This is the free Material Data Center Datasheet of MAGNUM™ 1150 EM - ABS - Trinseo

Material Data Center offers the following functions for MAGNUM™ 1150 EM:
unit conversion, PDF datasheet print, comparison with other plastics

Check here, which other Magnum datasheets, application examples or technical articles are available in Material Data Center

Use the following short links to get directly to the properties of interest in this datasheet:
Any use of this information falls under the rules of our disclaimer.
Processing/Physical Characteristics단위시험규격
ASTM 데이터
용융 흐름성, MFI 0.9 g/10min ASTM D 1238
온도 230 °C -
하중 3.8 kg -
성형 수축률, 평행 0.0065 mm/mm ASTM D 955
기계적 특성단위시험규격
ASTM 데이터
인장탄성률 1751 MPa ASTM D 638
항복강도 36.5 MPa ASTM D 638
항복변형률 3 % ASTM D 638
파단시 신율 30 % ASTM D 638
굴곡 계수 1979 MPa ASTM D 790
굴곡 강도 58.9 MPa ASTM D 790
아이조드 충격은 노치, 1/8 in 534 J/m ASTM D 256
아이조드 충격은 노치, Low-Temperature 336 J/m ASTM D 256
온도 -28.9 °C -
열적 특성단위시험규격
ASTM 데이터
열팽창 계수, 평행 95.4 E-6/K ASTM D 696
DTUL @ 66 psi 96.1 °C ASTM D 648
DTUL @ 264 psi 82.2 °C ASTM D 648
비카트 연화 온도 112 °C ASTM D 1525
기타 특성단위시험규격
밀도 1030 kg/m³ ASTM D 792
Processing Recommendation Injection Molding단위시험규격
Pre-drying - Temperature 82.2 °C -
Pre-drying - Time 2 - 4 h -
Processing humidity ≤0.1 % -
용융수지온도 218 - 274 °C -
성형온도 26.7 - 60 °C -
Back pressure 1.03 - 3.45 MPa -
특징
생산 공정
사출 성형, 외형 압출, 시트 압출, 열성형
특별 특성
도금가능한, 고충격 또는 고충격 보강
응용
자동차의
지역별 검색
쨘횕쩐횈쨍횧쨍짰횆짬, 쨀짼쨘횓 쨔횞 횁횩쩐횙 쩐횈쨍횧쨍짰횆짬
Disclaimer
Copyright Altair Engineering GmbH. Altair Engineering GmbH assumes no liability for the system to be free of errors. The user takes sole responsibility for the use of this data under the exclusion of every liability from Altair Engineering GmbH; this is especially valid for claims of compensation resulting from consequential damages. Altair explicitly points out that any decision about the application of materials must be double checked with the producer of this material. This includes all contents of this system. Copyright laws are applicable for the content of this system.
Created: Source: www.materialdatacenter.com


Material Data Center is provided by M-Base Engineering + Software GmbH. M-Base Engineering + Software GmbH assumes no liability for the system to be free of errors. Any decision about the application of materials must be double checked with the producer of this material.

Additional information about this material, like producer contact address, etc. can be found at www.materialdatacenter.com. For access to this extra information a registration is requested. Free online registration is available.