Material Data Center is a leading international information system for the plastics industry. Material Data Center offers a comprehensive plastics database, calculation tools, CAE interfaces, a literature database and an application database. For more information about Material Data Center visit www.materialdatacenter.com.

This is the free Material Data Center Datasheet of Vampter 4554 V0 60 F 20 - PBT-(MX+GF)45 - VAMP TECH SPA

Material Data Center offers the following functions for Vampter 4554 V0 60 F 20:
unit conversion, PDF datasheet print, comparison with other plastics

Check here, which other Vampter datasheets, application examples or technical articles are available in Material Data Center

Use the following short links to get directly to the properties of interest in this datasheet:
Any use of this information falls under the rules of our disclaimer.
Processing/Physical Characteristics단위시험규격
ASTM 데이터
성형 수축률, 평행 0.004 mm/mm ASTM D 955
성형 수축률, 수직 0.007 mm/mm ASTM D 955
기계적 특성단위시험규격
ISO 데이터
Izod충격강도, +23°C 40 kJ/m² ISO 180/1U
아이조드 충격은 노치, +23°C 7 kJ/m² ISO 180/1A
ASTM 데이터
인장탄성률 8000 MPa ASTM D 638
항복강도 75 MPa ASTM D 638
파단시 신율 2 % ASTM D 638
열적 특성단위시험규격
ISO 데이터
1.5mm 평균두께에서의 난연성 V-0 class IEC 60695-11-10
테스트 두께 1.6 mm -
두께 H인 제품의 난연성 V-0 class IEC 60695-11-10
테스트 두께 0.8 mm -
ASTM 데이터
DTUL @ 264 psi 205 °C ASTM D 648
비카트 연화 온도 205 °C ASTM D 1525
전기적 특성단위시험규격
ISO 데이터
CTI 600 - IEC 60112
기타 특성단위시험규격
밀도 1670 kg/m³ ASTM D 792
Processing Recommendation Injection Molding단위시험규격
Pre-drying - Temperature 110 °C -
Pre-drying - Time 3 h -
용융수지온도 250 °C -
성형온도 90 °C -
특징
생산 공정
사출 성형
특별 특성
난연성
Certifications
RoHS
지역별 검색
짱쨌쨈
Disclaimer
Copyright Altair Engineering GmbH. Altair Engineering GmbH assumes no liability for the system to be free of errors. The user takes sole responsibility for the use of this data under the exclusion of every liability from Altair Engineering GmbH; this is especially valid for claims of compensation resulting from consequential damages. Altair explicitly points out that any decision about the application of materials must be double checked with the producer of this material. This includes all contents of this system. Copyright laws are applicable for the content of this system.
Created: Source: www.materialdatacenter.com


Material Data Center is provided by M-Base Engineering + Software GmbH. M-Base Engineering + Software GmbH assumes no liability for the system to be free of errors. Any decision about the application of materials must be double checked with the producer of this material.

Additional information about this material, like producer contact address, etc. can be found at www.materialdatacenter.com. For access to this extra information a registration is requested. Free online registration is available.