Complete Set of CAMPUS® Data, ASTM Data, Biopolymer Database, Application Database, Tradename Database, Literature Database, Toolbox.

Material datasheets available free. Online registration at: www.materialdatacenter.com

Material Data Center is a leading international information system for the plastics industry. Material Data Center offers a comprehensive plastics database, calculation tools, CAE interfaces, a literature database and an application database. For more information about Material Data Center visit www.materialdatacenter.com.

This is the free Material Data Center Datasheet of DAUNYL® B R300 - PA6-GF30 - Daunia Plastics Srl

Material Data Center offers the following functions for DAUNYL® B R300:
unit conversion, PDF datasheet print, comparison with other plastics, snap fit calculation, beam deflection calculation, CAE Interfaces

Check here, which other Daunyl datasheets, application examples or technical articles are available in Material Data Center

Use the following short links to get directly to the properties of interest in this datasheet:
Any use of this information falls under the rules of our disclaimer.
Processing/Physical Characteristics단위시험규격
ISO 데이터
성형 수축률, 평행 0.5 % ISO 294-4, 2577
기계적 특성단위시험규격
ISO 데이터
인장탄성률 9500 MPa ISO 527
파단시 강도 180 MPa ISO 527
파단시 신율 3 % ISO 527
아이조드 충격은 노치, +23°C 12 kJ/m² ISO 180/1A
열적 특성단위시험규격
ISO 데이터
하중하에서의 변형온도, 1.80 MPa 205 °C ISO 75-1/-2
하중하에서의 변형온도, 0.45 MPa 215 °C ISO 75-1/-2
비카트 연화 온도, A 220 °C ISO 306
1.5mm 평균두께에서의 난연성 HB class IEC 60695-11-10
테스트 두께 1.6 mm -
두께 H인 제품의 난연성 HB class IEC 60695-11-10
테스트 두께 3.2 mm -
Glow Wire Flammability Index (GWFI) 650 °C IEC 60695-2-12
전기적 특성단위시험규격
ISO 데이터
CTI 600 - IEC 60112
기타 특성단위시험규격
밀도 1360 kg/m³ ISO 1183
Processing Recommendation Injection Molding단위시험규격
Pre-drying - Temperature 80 - 90 °C -
Pre-drying - Time >3 h -
용융수지온도 230 - 270 °C -
성형온도 70 - 90 °C -
특징
생산 공정
사출 성형
인도 유형
검정, 자연 색상
지역별 검색
짱쨌쨈
Disclaimer
Copyright Altair Engineering GmbH. Altair Engineering GmbH assumes no liability for the system to be free of errors. The user takes sole responsibility for the use of this data under the exclusion of every liability from Altair Engineering GmbH; this is especially valid for claims of compensation resulting from consequential damages. Altair explicitly points out that any decision about the application of materials must be double checked with the producer of this material. This includes all contents of this system. Copyright laws are applicable for the content of this system.
Created: Source: www.materialdatacenter.com


Material Data Center is provided by M-Base Engineering + Software GmbH. M-Base Engineering + Software GmbH assumes no liability for the system to be free of errors. Any decision about the application of materials must be double checked with the producer of this material.

Additional information about this material, like producer contact address, etc. can be found at www.materialdatacenter.com. For access to this extra information a registration is requested. Free online registration is available.