Material Data Center is a leading international information system for the plastics industry. Material Data Center offers a comprehensive plastics database, calculation tools, CAE interfaces, a literature database and an application database. For more information about Material Data Center visit www.materialdatacenter.com.

This is the free Material Data Center Datasheet of LUMID GP3200A(W) - PA6-MF20 - LG Chem

Material Data Center offers the following functions for LUMID GP3200A(W):
unit conversion, PDF datasheet print, comparison with other plastics

Check here, which other Lumid datasheets, application examples or technical articles are available in Material Data Center

Use the following short links to get directly to the properties of interest in this datasheet:
Any use of this information falls under the rules of our disclaimer.
Processing/Physical Characteristics단위시험규격
ASTM 데이터
성형 수축률, 평행 0.01 mm/mm ASTM D 955
기계적 특성단위시험규격
ASTM 데이터
항복강도 73.6 MPa ASTM D 638
파단시 신율 5 % ASTM D 638
굴곡 계수 4316 MPa ASTM D 790
굴곡 강도 113 MPa ASTM D 790
로크웰 경도 R 121 - ASTM D 785
아이조드 충격은 노치, 1/4 in 47.1 J/m ASTM D 256
열적 특성단위시험규격
ASTM 데이터
UL94 난연성 HB - UL 94
테스트 두께 0.75 mm -
열팽창 계수, 평행 56 E-6/K ASTM D 696
DTUL @ 264 psi 130 °C ASTM D 648
녹는점 220 °C ASTM D 3418
전기적 특성단위시험규격
ASTM 데이터
전기 압력, 단기간의 22 kV/mm ASTM D 149
상대 유전율, 1 MHz 4 - ASTM D 150
부피 저항 1E17 Ohm*cm ASTM D 257
아크 저항 185 s ASTM D 495
기타 특성단위시험규격
물에서의 흡수성, 24hr 1.2 % ASTM D 570
밀도 1280 kg/m³ ASTM D 792
Processing Recommendation Injection Molding단위시험규격
Pre-drying - Temperature 80 - 100 °C -
Pre-drying - Time 4 - 5 h -
용융수지온도 250 - 270 °C -
성형온도 60 - 80 °C -
Zone 1 230 - 255 °C -
Zone 2 245 - 260 °C -
Zone 3 245 - 270 °C -
Nozzle temperature 250 - 270 °C -
특징
생산 공정
사출 성형
응용
전기 및 전자 , 범용
지역별 검색
쨘횕쩐횈쨍횧쨍짰횆짬, 짱쨌쨈, 쩐횈쩍횄쩐횈 횇횂횈챵쩐챌 횁철쩔짧, 쨀짼쨘횓 쨔횞 횁횩쩐횙 쩐횈쨍횧쨍짰횆짬
Disclaimer
Copyright Altair Engineering GmbH. Altair Engineering GmbH assumes no liability for the system to be free of errors. The user takes sole responsibility for the use of this data under the exclusion of every liability from Altair Engineering GmbH; this is especially valid for claims of compensation resulting from consequential damages. Altair explicitly points out that any decision about the application of materials must be double checked with the producer of this material. This includes all contents of this system. Copyright laws are applicable for the content of this system.
Created: Source: www.materialdatacenter.com


Material Data Center is provided by M-Base Engineering + Software GmbH. M-Base Engineering + Software GmbH assumes no liability for the system to be free of errors. Any decision about the application of materials must be double checked with the producer of this material.

Additional information about this material, like producer contact address, etc. can be found at www.materialdatacenter.com. For access to this extra information a registration is requested. Free online registration is available.