Complete Set of CAMPUS® Data, ASTM Data, Biopolymer Database, Application Database, Tradename Database, Literature Database, Toolbox.

Material datasheets available free. Online registration at: www.materialdatacenter.com

Material Data Center is a leading international information system for the plastics industry. Material Data Center offers a comprehensive plastics database, calculation tools, CAE interfaces, a literature database and an application database. For more information about Material Data Center visit www.materialdatacenter.com.

This is the free Material Data Center Datasheet of Ultradur® S 4090 GX - (PBT+ASA)-GF14 - BASF

Material Data Center offers the following functions for Ultradur® S 4090 GX:
unit conversion, PDF datasheet print, comparison with other plastics, snap fit calculation, beam deflection calculation, parameters for material models, CAE Interfaces

Check here, which other Ultradur datasheets, application examples or technical articles are available in Material Data Center

Use the following short links to get directly to the properties of interest in this datasheet:
Any use of this information falls under the rules of our disclaimer.
제품 설명서
Low-warpage injection molding grade with 14 % glass fibres for technical parts, for which dimensional stability is very important (e.g.housings, plug-and-socket connectors).

Abbreviated designation according to ISO 1043: PBT-ASA-GF14
Processing/Physical Characteristics단위시험규격
ISO 데이터
용융 부피 - 흐름 속도, MVR 23 cm³/10min ISO 1133
온도 275 °C -
하중 2.16 kg -
성형 수축률, 평행 0.5 % ISO 294-4, 2577
성형 수축률, 수직 0.8 % ISO 294-4, 2577
기계적 특성단위시험규격
ISO 데이터
인장탄성률 5500 MPa ISO 527
파단시 강도 95 MPa ISO 527
파단시 신율 3.2 % ISO 527
챠피 충격 강도 , +23°C 52 kJ/m² ISO 179/1eU
챠피 충격 강도, -30°C 43 kJ/m² ISO 179/1eU
챠피 노치드 충격 강도, +23°C 7 kJ/m² ISO 179/1eA
열적 특성단위시험규격
ISO 데이터
녹는점, 10°C/min 223 °C ISO 11357-1/-3
하중하에서의 변형온도, 1.80 MPa 170 °C ISO 75-1/-2
하중하에서의 변형온도, 0.45 MPa 210 °C ISO 75-1/-2
선형 열팽창 계수, 평행 45 E-6/K ISO 11359-1/-2
선형 열팽창 계수, 수직 120 E-6/K ISO 11359-1/-2
1.5mm 평균두께에서의 난연성 HB class IEC 60695-11-10
테스트 두께 1.5 mm -
두께 H인 제품의 난연성 HB class IEC 60695-11-10
테스트 두께 0.8 mm -
전기적 특성단위시험규격
ISO 데이터
상대 유전율, 100Hz 3.6 - IEC 62631-2-1
상대 유전뮬, 1MHz 3.4 - IEC 62631-2-1
소산 인자, 100Hz 39 E-4 IEC 62631-2-1
소산 인자, 1MHz 208 E-4 IEC 62631-2-1
부피 저항 >1E13 Ohm*m IEC 62631-3-1
표면 저항 1E14 Ohm IEC 62631-3-2
전기 압력 42 kV/mm IEC 60243-1
CTI 375 - IEC 60112
기타 특성단위시험규격
물에서의 흡수성 0.4 % ISO 62와 유사
조건에서의 흡습성 0.2 % ISO 62와 유사
밀도 1330 kg/m³ ISO 1183
물질의 비성질단위시험규격
ISO 데이터
점도수 110 cm³/g ISO 307, 1157, 1628
Processing Recommendation Injection Molding단위시험규격
Pre-drying - Temperature 80 - 120 °C -
Pre-drying - Time 4 h -
Processing humidity ≤0.04 % -
용융수지온도 250 - 275 °C -
성형온도 60 - 100 °C -
도표
점도-변형률 , Ultradur® S 4090 GX, (PBT+ASA)-GF14, BASF
전단-변형률 , Ultradur® S 4090 GX, (PBT+ASA)-GF14, BASF
응력-신율 , Ultradur® S 4090 GX, (PBT+ASA)-GF14, BASF
시컨트탄성율-신율 , Ultradur® S 4090 GX, (PBT+ASA)-GF14, BASF
비용적-온도(pvT) , Ultradur® S 4090 GX, (PBT+ASA)-GF14, BASF
인장탄성율-온도 , Ultradur® S 4090 GX, (PBT+ASA)-GF14, BASF
특징
생산 공정
사출 성형
인도 유형
펠렛 (입자,알갱이)
부가물
윤활제
특별 특성
가시광선 안정성, U.V. 안정성 또는 기후 안정성, 열안정성
지역별 검색
기타 정보
사E성
PREPROCESSING
Pre/Post-processing, max. allowed water content: .04 %
Pre/Post-processing, Pre-drying, Temperature: 80 - 120 °C
Pre/Post-processing, Pre-drying, Time: 4 h

PROCESSING
injection molding, Melt temperature, range: 250 - 275 °C
injection molding, Melt temperature, recommended: 270 °C
injection molding, Mold temperature, range: 60 - 100 °C
injection molding, Mold temperature, recommended: 80 °C
Disclaimer
Copyright Altair Engineering GmbH. Altair Engineering GmbH assumes no liability for the system to be free of errors. The user takes sole responsibility for the use of this data under the exclusion of every liability from Altair Engineering GmbH; this is especially valid for claims of compensation resulting from consequential damages. Altair explicitly points out that any decision about the application of materials must be double checked with the producer of this material. This includes all contents of this system. Copyright laws are applicable for the content of this system.
Created: Source: www.materialdatacenter.com


Material Data Center is provided by M-Base Engineering + Software GmbH. M-Base Engineering + Software GmbH assumes no liability for the system to be free of errors. Any decision about the application of materials must be double checked with the producer of this material.

Additional information about this material, like producer contact address, etc. can be found at www.materialdatacenter.com. For access to this extra information a registration is requested. Free online registration is available.