Complete Set of CAMPUS® Data, ASTM Data, Biopolymer Database, Application Database, Tradename Database, Literature Database, Toolbox.

Material datasheets available free. Online registration at: www.materialdatacenter.com

Material Data Center is a leading international information system for the plastics industry. Material Data Center offers a comprehensive plastics database, calculation tools, CAE interfaces, a literature database and an application database. For more information about Material Data Center visit www.materialdatacenter.com.

This is the free Material Data Center Datasheet of TROGAMID® Care MX97 - PAPACM12 - Evonik Operations GmbH

Material Data Center offers the following functions for TROGAMID® Care MX97:
unit conversion, PDF datasheet print, comparison with other plastics, snap fit calculation, beam deflection calculation, CAE Interfaces

Check here, which other Trogamid datasheets, application examples or technical articles are available in Material Data Center

Use the following short links to get directly to the properties of interest in this datasheet:
Any use of this information falls under the rules of our disclaimer.
Informação do produto
Microcrystalline and transparent polyamides for for medical application

TROGAMID® Care MX is the material of choice for all applications dealing with pharmaceutical formulations, lipids or aggressive disinfectants, since it exhibits an exceptional resistance towards chemicals and stress-cracking. Examples include fluid and drug delivery equipment such as stop-cocks, dialyzer parts, housings, covers or hearing aids.
 
Target areas of application for TROGAMID® Care MX compounds include fluid and drug delivery systems, surgical instruments, housings, monitoring and imaging devices and durable medical equipment.
 
All advantages at a glance
- High transparency 
- High chemical resistance 
- Very good stress crack resistance
- UV resistance
- High dynamic load-bearing capacity
- High impact resistance
- Easy processability & colorability
- Free of BPA
- Gamma and EtO sterilizable

Biocompatibility of TROGAMID® Care
TROGAMID® Care grades were tested on biocompatibility for applications within the body of up to 30 days contact time and comply with USP <88> class VI and ISO 10993 standards.

Biocompatibility tests for TROGAMID® Care:


Processing of TROGAMID® Care
For information about processing of TROGAMID®, please follow the general commendations about “Processing of TROGAMID® compounds”.  

FOR FURTHER INFORMATION PLEASE CONTACT US AT EVONIK-HP@EVONIK.COM
OR VISIT OUR PRODUCT AT  WWW.EVONIK.COM/MEDICAL-TECHNOLOGY
Características de processamento/físicasSeco / CondUnidadeMétodo de ensaio
ISO Dados
Índice de fluidez volumétrico, MVR 31 / * cm³/10min ISO 1133
Temperatura 285 / * °C -
Carga 5 / * kg -
Contração após a moldagem, paralelo 0.7 / * % ISO 294-4, 2577
Contração após a moldagem, perpendicular 0.8 / * % ISO 294-4, 2577
Propriedades mecânicasSeco / CondUnidadeMétodo de ensaio
ISO Dados
Módulo de tração 1400 / - MPa ISO 527
Tensão no escoamento 60 / - MPa ISO 527
Deformação no escoamento 8 / - % ISO 527
Deformação nominal na ruptura >50 / - % ISO 527
Resistência ao impacto Charpy , +23°C N / - kJ/m² ISO 179/1eU
Resistência ao impacto Charpy, -30°C N / - kJ/m² ISO 179/1eU
Res. impacto Charpy c/entalhe, +23°C 14 / 10.5 kJ/m² ISO 179/1eA
Type of failure C / C - -
Res. impacto Charpy c/entalhe, -30°C 13 / - kJ/m² ISO 179/1eA
Type of failure C / - - -
Dureza Shore D 81 / * - ISO 7619-1
Propriedades térmicasSeco / CondUnidadeMétodo de ensaio
ISO Dados
Temperatura de fusão, 10°C/min 250 / * °C ISO 11357-1/-3
Temp. de transição vítrea, 10°C/min 140 / * °C ISO 11357-1/-2
Temperatura de deflexão térmica, 1.80 MPa 108 / * °C ISO 75-1/-2
Temperatura de deflexão térmica, 0.45 MPa 122 / * °C ISO 75-1/-2
Temperatura de amolecimento Vicat, B 130 / * °C ISO 306
Coef. de expansão térmica linear, paralelo 90 / * E-6/K ISO 11359-1/-2
Coef. de expansão térmica linear, perpend. 90 / * E-6/K ISO 11359-1/-2
Flamabilidade a 1.5mm esp. nom. HB / * class IEC 60695-11-10
Espessuras do tubo de teste 1.6 / * mm -
Flamabilidade a espessura h HB / * class IEC 60695-11-10
Espessuras do tubo de teste 0.8 / * mm -
Propriedades elétricasSeco / CondUnidadeMétodo de ensaio
ISO Dados
Constante dielétrica, 100Hz 3.6 / - - IEC 62631-2-1
Constante dielétrica, 1MHz 3.2 / - - IEC 62631-2-1
Fator de dissipação dielétrica, 100Hz 120 / - E-4 IEC 62631-2-1
Fator de dissipação dielétrica, 1MHz 325 / - E-4 IEC 62631-2-1
Índice comparativo de linha de fuga 600 / - - IEC 60112
Outras propriedadesSeco / CondUnidadeMétodo de ensaio
Absorção de água 3.5 / * % Sim. to ISO 62
Absorção de umidade 1.5 / * % Sim. to ISO 62
Densidade 1020 / - kg/m³ ISO 1183
Características
Processamento
Moldagem por injeção, Extrusão de laminas, Extrusão de perfis, Extrusão de chapas
Forma de entrega
Granulos
Aditivos
Desmoldante
Características especiais
Alto impacto., Estabilidade a raios U.V./Intempéries, Transparente, Esterilizável, Esterilização por óxido de etileno (EtO), Gamma irradiation sterilization
Resistência Química
Resistência química geral, Resistência ao stress cracking
Certifications
Grau médico, Biocompatibility ISO 10993, USP Class VI
Aplicaciones
Médico
Disponibilidade regional
América do Norte, Europa, Ásia Pacífico, America Centra e do Sul, Oriente/África
Disclaimer
Copyright Altair Engineering GmbH. Altair Engineering GmbH assumes no liability for the system to be free of errors. The user takes sole responsibility for the use of this data under the exclusion of every liability from Altair Engineering GmbH; this is especially valid for claims of compensation resulting from consequential damages. Altair explicitly points out that any decision about the application of materials must be double checked with the producer of this material. This includes all contents of this system. Copyright laws are applicable for the content of this system.
Created: Source: www.materialdatacenter.com


Material Data Center is provided by M-Base Engineering + Software GmbH. M-Base Engineering + Software GmbH assumes no liability for the system to be free of errors. Any decision about the application of materials must be double checked with the producer of this material.

Additional information about this material, like producer contact address, etc. can be found at www.materialdatacenter.com. For access to this extra information a registration is requested. Free online registration is available.