Complete Set of CAMPUS® Data, ASTM Data, Biopolymer Database, Application Database, Tradename Database, Literature Database, Toolbox.

Material datasheets available free. Online registration at: www.materialdatacenter.com

Material Data Center is a leading international information system for the plastics industry. Material Data Center offers a comprehensive plastics database, calculation tools, CAE interfaces, a literature database and an application database. For more information about Material Data Center visit www.materialdatacenter.com.

This is the free Material Data Center Datasheet of VESTAMID® Care ME47 - TPA - Evonik Operations GmbH

Material Data Center offers the following functions for VESTAMID® Care ME47:
unit conversion, PDF datasheet print, comparison with other plastics, snap fit calculation, beam deflection calculation, CAE Interfaces

Check here, which other Vestamid datasheets, application examples or technical articles are available in Material Data Center

Use the following short links to get directly to the properties of interest in this datasheet:
Any use of this information falls under the rules of our disclaimer.
Informação do produto
Polyamide 12 elastomer molding compounds

VESTAMID® Care ME47 is free of plasticizers and heat and light stabilized. VESTAMID® Care ME47 is resistant to body fluids and toxicologically safe.

VESTAMID® Care ME grades are flexible polyether block amides (PEBA) resins.

The advantages at a glance
- High flexibility & elasticity
- High impact resistance
- Excellent dimensional stability
- High chemical resistance
- Easy processability & colorability

- Plasticizer-free

- Gamma and EtO sterilization resistant

- Tough and resilient

- Low density


Biocompatibility of VESTAMID® Care ME
VESTAMID® Care ME grades were tested on biocompatibility for applications within the body of up to 30 days contact time and comply with USP <88> class VI and ISO 10993 standards.

Biocompatibility tests for VESTAMID® Care:
Standard Description
ASTM F756-08 Hemocompatibility
ISO 10993-5 Cytotoxicity
ISO 10993-10 Sensitization: Maximization test according to Magnusson and Kligman
ISO 10993-10 Irritation: Intracutaneous Reactivity
ISO 10993-11 Acute Systemic Toxicity
USP Class VI Acute Systemic Toxicity Intracutaneous Reactivity Muscle Implantation
Processing of VESTAMID® Care
For information about processing of VESTAMID®, please follow the general commendations about “Processing of VESTAMID® compounds”.   


FOR FURTHER INFORMATION PLEASE CONTACT US AT EVONIK-HP@EVONIK.COM
OR VISIT OUR PRODUCT AT  WWW.EVONIK.COM/MEDICAL-TECHNOLOGY
Características de processamento/físicasSeco / CondUnidadeMétodo de ensaio
ISO Dados
Índice de fluidez volumétrico, MVR 28 / * cm³/10min ISO 1133
Temperatura 240 / * °C -
Carga 2.16 / * kg -
Contração após a moldagem, paralelo 0.3 / * % ISO 294-4, 2577
Contração após a moldagem, perpendicular 0.8 / * % ISO 294-4, 2577
Propriedades mecânicasSeco / CondUnidadeMétodo de ensaio
ISO Dados
Módulo de tração 125 / - MPa ISO 527
Módulo de tensão de fluência, 1000h * / 90 MPa ISO 899-1
Resistência ao impacto Charpy , +23°C N / - kJ/m² ISO 179/1eU
Resistência ao impacto Charpy, -30°C N / - kJ/m² ISO 179/1eU
Res. impacto Charpy c/entalhe, +23°C N / - kJ/m² ISO 179/1eA
Res. impacto Charpy c/entalhe, -30°C N / - kJ/m² ISO 179/1eA
Dureza Shore D 47 / * - ISO 7619-1
Propriedades térmicasSeco / CondUnidadeMétodo de ensaio
ISO Dados
Temperatura de fusão, 10°C/min 157 / * °C ISO 11357-1/-3
Temp. de transição vítrea, 10°C/min -50 / * °C ISO 11357-1/-2
Temperatura de deflexão térmica, 1.80 MPa 45 / * °C ISO 75-1/-2
Temperatura de deflexão térmica, 0.45 MPa 65 / * °C ISO 75-1/-2
Temperatura de amolecimento Vicat, B 70 / * °C ISO 306
Coef. de expansão térmica linear, paralelo 230 / * E-6/K ISO 11359-1/-2
Coef. de expansão térmica linear, perpend. 210 / * E-6/K ISO 11359-1/-2
Flamabilidade a 1.5mm esp. nom. HB / * class IEC 60695-11-10
Espessuras do tubo de teste 1.6 / * mm -
Propriedades elétricasSeco / CondUnidadeMétodo de ensaio
ISO Dados
Constante dielétrica, 100Hz 8.5 / - - IEC 62631-2-1
Constante dielétrica, 1MHz 4.7 / - - IEC 62631-2-1
Fator de dissipação dielétrica, 100Hz 1200 / - E-4 IEC 62631-2-1
Fator de dissipação dielétrica, 1MHz 1300 / - E-4 IEC 62631-2-1
Resistividade volumétrica específica 1E9 / - Ohm*m IEC 62631-3-1
Outras propriedadesSeco / CondUnidadeMétodo de ensaio
Absorção de água 1 / * % Sim. to ISO 62
Absorção de umidade 0.4 / * % Sim. to ISO 62
Densidade 1020 / - kg/m³ ISO 1183
Características
Processamento
Moldagem por injeção
Forma de entrega
Granulos
Características especiais
Alto impacto., Estável a luz, Estável contra o calor, Esterilizável, Esterilização por óxido de etileno (EtO), Gamma irradiation sterilization
Resistência Química
Resistência química geral
Certifications
Grau médico, Biocompatibility ISO 10993, USP Class VI
Aplicaciones
Médico
Disponibilidade regional
Disclaimer
Copyright Altair Engineering GmbH. Altair Engineering GmbH assumes no liability for the system to be free of errors. The user takes sole responsibility for the use of this data under the exclusion of every liability from Altair Engineering GmbH; this is especially valid for claims of compensation resulting from consequential damages. Altair explicitly points out that any decision about the application of materials must be double checked with the producer of this material. This includes all contents of this system. Copyright laws are applicable for the content of this system.
Created: Source: www.materialdatacenter.com


Material Data Center is provided by M-Base Engineering + Software GmbH. M-Base Engineering + Software GmbH assumes no liability for the system to be free of errors. Any decision about the application of materials must be double checked with the producer of this material.

Additional information about this material, like producer contact address, etc. can be found at www.materialdatacenter.com. For access to this extra information a registration is requested. Free online registration is available.