Complete Set of CAMPUS® Data, ASTM Data, Biopolymer Database, Application Database, Tradename Database, Literature Database, Toolbox.

Material datasheets available free. Online registration at: www.materialdatacenter.com

Material Data Center is a leading international information system for the plastics industry. Material Data Center offers a comprehensive plastics database, calculation tools, CAE interfaces, a literature database and an application database. For more information about Material Data Center visit www.materialdatacenter.com.

This is the free Material Data Center Datasheet of Pebax® MV 1074 SA 01 MED - TPA - ARKEMA

Material Data Center offers the following functions for Pebax® MV 1074 SA 01 MED:
unit conversion, PDF datasheet print, comparison with other plastics, snap fit calculation, beam deflection calculation, CAE Interfaces

Check here, which other Pebax datasheets, application examples or technical articles are available in Material Data Center

Use the following short links to get directly to the properties of interest in this datasheet:
Any use of this information falls under the rules of our disclaimer.
材料文字说明
Polyether block amide Pebax® MV 1074 SA 01 MED resin is a thermoplastic elastomer made of flexible and hydrophilic polyether and rigid polyamide.
Hydrophilic Pebax® MV 1074 SA 01 MED resin is suitable for extrusion or coextrusion and offers excellent high moisture absorption properties in wet environments, enhancing lubricity against bodily tissue.
Pebax® MV 1074 SA 01 MED resin is also an inherently dissipative polymer and can be dry blended or compounded with a polymer matrix to lower the surface resistivity of the final part.
This grade offers the highest quality and it is specially designed to meet the stringent requirements of the medical applications such as minimally invasive devices. Upon request, letters regarding USP Class VI compliance can be provided.

Refractive index according to an internal method is 1.502.

Main applications:
  • Breathable membranes
  • Permanent antistactic additive
  • Surgical tubings and garments


Packaging:

This grade is delivered dried in sealed packaging (25 kg bags) ready to be processed.

Shelf Life:
Two years from the delivery. For any use above this limit, please refer to our technical services.
机械性能干 / 已调节单位Test Standard
ISO数据
拉伸模量 97 / 80 MPa ISO 527
50%伸长率时的应力S 10 / 10 MPa ISO 527
断裂伸长率 >50 / >50 % ISO 527
断裂应力 TPE 30 / * MPa ISO 527
断裂应变 TPE >300 / * % ISO 527
肖氏硬度D 38 / * - ISO 7619-1
热性能干 / 已调节单位Test Standard
ISO数据
熔融温度, 10°C/min 158 / * °C ISO 11357-1/-3
玻璃化转变温度, 10°C/min -40 / * °C ISO 11357-1/-2
燃烧性-氧指数 19 / * % ISO 4589-1/-2
电性能干 / 已调节单位Test Standard
ISO数据
体积电阻率 1.5E9 / 2.5E7 Ohm*m IEC 62631-3-1
表面电阻率 * / 3E9 Ohm IEC 62631-3-2
介电强度 5 / - kV/mm IEC 60243-1
其它性能干 / 已调节单位Test Standard
吸湿性 1.4 / * % 类似ISO 62
密度 1070 / - kg/m³ ISO 1183
机械性能(薄膜)干 / 已调节单位Test Standard
ISO数据
最大应力, 平行 32 / * MPa ISO 527-3
最大应力, 垂直 34 / * MPa ISO 527-3
最大应变, 平行 500 / * % ISO 527-3
最大应变, 垂直 700 / * % ISO 527-3
典型数据
加工方法
注塑, 其它挤出成型
特殊性能
防静电的, 经光稳处理的/耐光的, 经热稳处理的/耐热的
Certifications
医用级, US药物六级认证
地区供应
北美, 欧洲, 亚太, 中南美洲, 中东/非洲
其他信息
注塑成型

Processing conditions:

- Typical melt temperature (Min / Recommended / Max): 200°C / 240°C / 270°C.
- Typical mold temperature: 25–60°C.
- Drying time and temperature (only necessary for bags opened for more than two hours): 4-6 hours at 65-75°C.
其E烦龀尚

Processing conditions:

- Typical melt temperature (Min / Recommended / Max): 210°C / 220°C / 230°C.
- Drying time and temperature (only necessary for bags opened for more than two hours): 4-6 hours at 65-75°C.
权利义务的法律声明
Copyright Altair Engineering GmbH. Altair Engineering GmbH assumes no liability for the system to be free of errors. The user takes sole responsibility for the use of this data under the exclusion of every liability from Altair Engineering GmbH; this is especially valid for claims of compensation resulting from consequential damages. Altair explicitly points out that any decision about the application of materials must be double checked with the producer of this material. This includes all contents of this system. Copyright laws are applicable for the content of this system.
Created: Source: www.materialdatacenter.com


Material Data Center is provided by M-Base Engineering + Software GmbH. M-Base Engineering + Software GmbH assumes no liability for the system to be free of errors. Any decision about the application of materials must be double checked with the producer of this material.

Additional information about this material, like producer contact address, etc. can be found at www.materialdatacenter.com. For access to this extra information a registration is requested. Free online registration is available.