Material Data Center is a leading international information system for the plastics industry. Material Data Center offers a comprehensive plastics database, calculation tools, CAE interfaces, a literature database and an application database. For more information about Material Data Center visit www.materialdatacenter.com.

This is the free Material Data Center Datasheet of VESTAMID® Care ML17 - PA12 - Evonik Operations GmbH

Material Data Center offers the following functions for VESTAMID® Care ML17:
unit conversion, PDF datasheet print, comparison with other plastics, snap fit calculation, beam deflection calculation, CAE Interfaces

Check here, which other Vestamid datasheets, application examples or technical articles are available in Material Data Center

Use the following short links to get directly to the properties of interest in this datasheet:
Any use of this information falls under the rules of our disclaimer.
材料文字说明
Low viscosity polyamide 12 for medical application

VESTAMID® Care ML17 is resistant to body fluids and toxicologically safe.
 

Typical application areas for filled VESTAMID Care ML grades include  catheters, housing parts, monitoring and imaging devices and durable medical equipment.

Advantages at a glance

- High impact resistance

- Easy processability & colorability

- Low sliding friction

- High toughness

- High abrasion resistance

- Density 1.0 g/cc

- High dimensional stability

- High chemical resistance

- Gamma and EtO sterilizable


Biocompatibility of VESTAMID® Care ML
VESTAMID® Care ML grades were tested on biocompatibility for applications within the body of up to 30 days contact time and comply with USP <88> class VI and ISO 10993 standards.

Biocompatibility tests for VESTAMID® Care:
Standard Description
ASTM F756-08 Hemocompatibility
ISO 10993-5 Cytotoxicity
ISO 10993-10 Sensitization: Maximization test according to Magnusson and Kligman
ISO 10993-10 Irritation: Intracutaneous Reactivity
ISO 10993-11 Acute Systemic Toxicity
USP Class VI Acute Systemic Toxicity Intracutaneous Reactivity Muscle Implantation
Processing of VESTAMID® Care
For information about processing of VESTAMID®, please follow the general commendations about “Processing of VESTAMID® compounds”. 
 

FOR FURTHER INFORMATION PLEASE CONTACT US AT EVONIK-HP@EVONIK.COM
OR VISIT OUR PRODUCT AT  WWW.EVONIK.COM/MEDICAL-TECHNOLOGY
加工/物理特性干 / 已调节单位Test Standard
ISO数据
熔体体积流动速度, MVR 21 / * cm³/10min ISO 1133
温度 210 / * °C -
载荷 2.16 / * kg -
模塑收缩率, 平行 0.7 / * % ISO 294-4, 2577
模塑收缩率, 垂直 1.2 / * % ISO 294-4, 2577
机械性能干 / 已调节单位Test Standard
ISO数据
拉伸模量 1400 / 1120 MPa ISO 527
屈服应力 43 / 41 MPa ISO 527
屈服伸长率 5 / 13 % ISO 527
名义断裂伸长率 >50 / 40 % ISO 527
无缺口简支梁冲击强度, +23°C N / N kJ/m² ISO 179/1eU
简支梁冲击强度, -30°C N / 50 kJ/m² ISO 179/1eU
Type of failure - / C(N) - -
简支梁缺口冲击强度, +23°C 4.5 / 4.5 kJ/m² ISO 179/1eA
Type of failure C / C - -
简支梁缺口冲击强度, -30°C 6 / 5 kJ/m² ISO 179/1eA
Type of failure C / C - -
肖氏硬度D 75 / * - ISO 7619-1
热性能干 / 已调节单位Test Standard
ISO数据
熔融温度, 10°C/min 178 / * °C ISO 11357-1/-3
玻璃化转变温度, 10°C/min 45 / * °C ISO 11357-1/-2
热变形温度, 1.80 MPa 50 / * °C ISO 75-1/-2
热变形温度, 0.45 MPa 110 / * °C ISO 75-1/-2
维卡软化温度, B 140 / * °C ISO 306
线性热膨胀系数, 平行 150 / * E-6/K ISO 11359-1/-2
1.5mm名义厚度时的燃烧性 HB / * class IEC 60695-11-10
测试用试样的厚度 1.6 / * mm -
电性能干 / 已调节单位Test Standard
ISO数据
相对介电常数., 100Hz 3.8 / - - IEC 62631-2-1
相对介电常数., 1MHz 2.9 / - - IEC 62631-2-1
介质损耗因子, 100Hz 500 / - E-4 IEC 62631-2-1
介质损耗因子, 1MHz 281 / - E-4 IEC 62631-2-1
体积电阻率 >1E13 / 2.3E12 Ohm*m IEC 62631-3-1
其它性能干 / 已调节单位Test Standard
吸水性 1.5 / * % 类似ISO 62
吸湿性 0.7 / * % 类似ISO 62
密度 1020 / - kg/m³ ISO 1183
典型数据
加工方法
注塑
供货形式
粒料
特殊性能
高冲击韧性的/经抗冲改性的, 消毒, 环氧乙烷灭菌(EtO), Gamma irradiation sterilization
特征
Tribologic Grade
耐化学试剂
通用耐化学性
Certifications
医用级, Biocompatibility ISO 10993, US药物六级认证
应用
药物
地区供应
权利义务的法律声明
Copyright Altair Engineering GmbH. Altair Engineering GmbH assumes no liability for the system to be free of errors. The user takes sole responsibility for the use of this data under the exclusion of every liability from Altair Engineering GmbH; this is especially valid for claims of compensation resulting from consequential damages. Altair explicitly points out that any decision about the application of materials must be double checked with the producer of this material. This includes all contents of this system. Copyright laws are applicable for the content of this system.
Created: Source: www.materialdatacenter.com


Material Data Center is provided by M-Base Engineering + Software GmbH. M-Base Engineering + Software GmbH assumes no liability for the system to be free of errors. Any decision about the application of materials must be double checked with the producer of this material.

Additional information about this material, like producer contact address, etc. can be found at www.materialdatacenter.com. For access to this extra information a registration is requested. Free online registration is available.